78
SBXL52: Hardware Maintenance Manual and Troubleshooting Guide
289
(DIMM disabled by POST or user)
1.
Run the Configuration/Setup Utility program, if the DIMM was
disabled by the user.
2.
Disabled DIMM, if not disabled by user.
3.
System board
301
(Keyboard or keyboard controller error)
1.
Keyboard
2.
System board
303
(Keyboard controller error)
•
System board
602
(Invalid diskette boot record)
1.
Diskette
2.
Diskette drive
3.
Cable
4.
System board
604
(Diskette drive error)
1.
Run the Configuration/Setup Utility program and diagnostics.
2.
Diskette drive.
3.
Drive cable.
4.
System board.
605
(Unlock failure)
1.
Diskette drive
2.
Drive cable
3.
System board
662
(Diskette drive configuration error)
1.
Run the Configuration/Setup Utility program and diagnostics.
2.
Diskette drive.
3.
Drive cable.
4.
System board.
762
(Coprocessor configuration error)
1.
Run the Configuration/Setup Utility program.
2.
Battery.
3.
Microprocessor.
962
(Parallel port configuration error)
1.
Run the Configuration/Setup Utility program and verify that the
parallel-port setting is correct.
2.
System board.
11XX
(System board serial port 1 or 2 error)
1.
Disconnect the external cable on the serial port.
2.
Run the Configuration/Setup Utility program.
3.
System board.
1162
(Serial port configuration conflicts)
1.
Run the Configuration/Setup Utility program and ensure that the
IRQ and I/O port assignments needed by the serial port are
available.
2.
If all interrupts are being used by adapters, remove an adapter or
force other adapters to share an interrupt.
✏
NOTE
See “System” on page 104 to determine which components should be replaced by a field service
technician.
Error code/symptom
FRU/action