SBXL52: Hardware Maintenance Manual and Troubleshooting Guide
3-3-2
(Critical SMBUS error occurred)
1.
Power down blade server and reseat it in chassis.
2.
DIMMs.
3.
System board.
3-3-3
(No operational memory in system)
✏
NOTE
In some memory
configurations, the 3-3-3
beep code might sound
during POST followed by a
blank display screen. If this
occurs and the Boot Fail
Count feature in the Start
Options of the
Configuration/Setup Utility is
set to Enabled (its default
setting), you must restart the
server three times to force
the system BIOS code to
reset the memory connector
or bank of connectors from
Disabled to Enabled.
1.
Install or reseat the memory modules, and then do a 3 boot reset.
(For more information on a 3 boot reset, see “Using the
Configuration/Setup Utility program” on page 11)
2.
DIMMs.
3.
System board.
Two short beeps
(Information only, the configuration
has changed)
1.
Run Diagnostics.
2.
Run the Configuration/Setup Utility program.
Three short beeps
1.
DIMM
2.
System board
One continuous beep
1.
Microprocessor
2.
Optional microprocessor (if installed)
3.
System board
Repeating short beeps
1.
Keyboard
2.
System board
✏
NOTE
See “System” on page 104 to determine which components should be replaced by a field service
technician.
Beep/symptom
FRU/action