SBXL52: Hardware Maintenance Manual and Troubleshooting Guide
DIMM x error
A memory error occurred.
1.
Reseat the DIMM indicated by the lit DIMM
failure LED.
2.
Replace the DIMM.
✏
NOTE
Multiple DIMM LEDs do not necessarily
indicate multiple DIMM failures. If more
than one DIMM LED is on,
reseat/replace one DIMM at a time until
error goes away. Refer to the SBCE
management module system error log
for further isolation.
Processor x
error
The microprocessor has failed.
1.
Verify that the microprocessor indicated by
the lit LED is installed correctly. (See
“Installing an additional microprocessor” on
page 38 for installation instructions).
2.
Replace the microprocessor.
Temperature
error
The system temperature has exceeded a
threshold level.
1.
Check to see if a blower on the SBCE unit
has failed. If it has, replace the fan.
2.
Make sure the room temperature is not too
high. (See “Features and specifications” on
page 2 for temperature information.)
System board
error
The system board has failed
1.
Replace the blade server cover, reinsert
the blade server in the SBCE unit, and
then restart the server.
2.
Replace the system board.
IDE bus x error
The IDE bus indicated by the error LED has
failed.
1.
Reseat/replace the hard disk drive on IDE
bus x.
2.
Replace the system board.
NMI error
The system board has failed.
1.
Replace the blade server cover, reinsert
the blade server in the SBCE unit, and
then restart the blade server.
2.
Check the system error log for information
about the error.
If the problem remains, replace the system
board.
Processor
mismatch
The processors do not match.
•
Verify that microprocessors 1 and 2 have
the same cache size and type and the
same clock speed. Internal and external
clock frequencies must be identical; also
see “Error symptoms” on page 83.
Lit blade-error
LED Cause
Action