89
Thermal Specifications
6.3
Platform Environment Control Interface (PECI)
6.3.1
Introduction
PECI offers an interface for thermal monitoring of Intel processor and chipset
components. It uses a single wire, thus alleviating routing congestion issues.
Figure 6-8
shows an example of the PECI topology in a system with Dual-Core Intel®
Xeon® Processor 5200 Series. PECI uses CRC checking on the host side to ensure
reliable transfers between the host and client devices. Also, data transfer speeds across
the PECI interface are negotiable within a wide range (2Kbps to 2Mbps). The PECI
interface on the Dual-Core Intel® Xeon® Processor 5200 Series is disabled by default
and must be enabled through BIOS.
6.3.1.1
T
CONTROL
and TCC Activation on PECI-based Systems
Fan speed control solutions based on PECI utilize a T
CONTROL
value stored in the
processor IA32_TEMPERATURE_TARGET MSR. The T
CONTROL
MSR uses the same offset
temperature format as PECI though it contains no sign bit. Thermal management
devices should infer the T
CONTROL
value as negative. Thermal management algorithms
should utilize the relative temperature value delivered over PECI in conjunction with the
T
CONTROL
MSR value to control or optimize fan speeds.
Figure 6-9
shows a conceptual
fan control diagram using PECI temperatures.
The relative temperature value reported over PECI represents the data below the onset
of thermal control circuit (TCC) activation as needed by PROCHOT# assertions. As the
temperature approaches TCC activation, the PECI value approaches zero. TCC activates
at a PECI count of zero.
Figure 6-8. Dual-Core Intel® Xeon® Processor 5200 Series PECI Topology
PEC I H ost
C ontroller
PECI
Processor
(Socket 0)
Processor
(Socket 1)
PECI
Pin
G 5
Pin
G 5
Dom ain0
0x
30
Dom ain0
0x31
Summary of Contents for L5310 - Cpu Xeon Quad-Core Lv 1.6Ghz Fsb1066Mhz 8M Fc-Lga6 Tray
Page 1: ...318590 005 Dual Core Intel Xeon Processor 5200 Series Datasheet August 2008...
Page 8: ...8 Dual Core Intel Xeon Processor 5200 Series Datasheet...
Page 14: ...14...
Page 92: ...Thermal Specifications 92...
Page 98: ...Features 98...
Page 102: ...Boxed Processor Specifications 102 Figure 8 4 Top Side Board Keepout Zones Part 1...
Page 103: ...103 Boxed Processor Specifications Figure 8 5 Top Side Board Keepout Zones Part 2...
Page 104: ...Boxed Processor Specifications 104 Figure 8 6 Bottom Side Board Keepout Zones...
Page 105: ...105 Boxed Processor Specifications Figure 8 7 Board Mounting Hole Keepout Zones...
Page 106: ...Boxed Processor Specifications 106 Figure 8 8 Volumetric Height Keep Ins...
Page 112: ...Boxed Processor Specifications 112...