Technical Data
INSYS Modem 56k small EU 2.1
10
4
Technical Data
4.1
Physical Features
Danger!
Overvoltage.
Fire hazard!
The modem must be secured with a suitable fuse against
overvoltage.
All specified data was measured with a nominal input voltage, at full load, and an ambi-
ent temperature of 25 °C. The threshold value tolerances are subject to typical fluctua-
tions.
Physical Feature
Value
Operating voltage
Minimum 10 V DC
Maximum 32 V DC
Power input sleep
2.4 W
Power input connection
2.6 W
Weight
100 g
Dimensions (Width x Depth x Height)
23 mm x 110 mm x 75 mm
Temperature range
0 °C – 55 °C
Maximum allowed humidity
95 % non-condensing
Table 1: Physical Features
4.2
Technological Features
Technological Feature
Description
Protection Class
Housing IP40
Terminals IP20
Supported data compression standards
MNP 2/3, MNP 5, V.42 bis; V.44, MNP 10,
MNP 10 EC
Fax-Classes
Fax Class 1
Modulation types
V.32bis, V.32, V.23, V.22, V22 bis, V21,
V.34+, V.34, V.42, (bei 56k-Version zusätz-
lich V.90 und V.92)Bell Norm 103/212
Error correction standards
MNP4, LAPM
Table 1: Technological Features