S Registry
INSYS Modem 56k small EU 2.1
66
16.2
Description S Registry
Note:
Registries marked with *) are stored in the user defaults with the command
AT&W
.
S0*
Number of ringing tones until automatically going off-hook
Number of rings until the modem goes off-hook
For S0=0 the modem will not go off-hook when a call comes in. The value of S0
can be between 0 and 5.
S1
Ring tone counter
Counter for call ringing. S1 is read-only. S1 will be reset to zero, when the modem
answers a call.
S2*
Escape
Escape character, which causes a switch from data mode to online command in-
put mode. Values larger than 127 will lead to the fact that no ESC character will be
recognized.
S3
Return
Carriage Return Character (CR).
S4
Line feed character
Line feed character
S5
Backspace
character
Backspace
character
S6*
Waiting period for dial tone
Maximum waiting time for the dialling tone. After the modem went off-hook it
waits 7 seconds for the dialling tone (fixed for approval purposes). If it detects a
dialling tone during this waiting period it will start dialling.
If it does not detect a dialling tone, it will check if dial tone recognition is activated
or if the dialling string (Section "
AT
Command Set", command
ATD
) contains the
parameter
W
. If the dialling tone detection is not activated, the modem waits for
the dialling tone.
The value of the S6 register can be between 4 and 7 seconds.
S7*
Waiting period for carrier signal
Wait for the carrier frequency from the other modem. The maximum time for the
modem to wait for a response from the other modem is specified in S7. The time
starts running as soon as the modem has finished dialling. The value of S7 can be
between 0 and 180 seconds.