Maintenance and
Troubleshooting
MD380 User Manual
- 302 -
SN
Symptom
Possible Causes
Solutions
6
The motor does
not rotate after the
AC drive runs.
1: Check the motor and the motor
cables.
2: The motor parameters are set
improperly.
3: The cable between the drive
board and the control board is in
poor contact.
4: The drive board is faulty.
1: Check that cabling between
the AC drive and the motor is
normal..
2: Replace the motor or rectify
mechanical faults.
3: Check and set the motor
parameters again.
7
The DI terminals
are disabled.
1: The related parameters are set
incorrectly.
2: The external signal is incorrect.
7KHMXPSHUDFURVV23DQG9
becomes loose.
4: The control board is faulty.
1: Check and set the parameters
in group F4 again.
2: Re-connect the external
signal cables.
5HFRQ¿UPWKHMXPSHUEDU
DFURVV23DQG9
4: Contact the agent or Inovance
for technical support.
8
The motor speed
is always low in
CLVC mode.
1: The encoder is faulty.
2: The encoder cable is connected
incorrectly or in poor contact.
3: The PG card is faulty.
4: The drive board is faulty.
1: Replace the encoder and
ensure the cabling is proper.
2: Replace the PG card.
3: Contact the agent or Inovance
for technical support.
9
The AC drive
reports overcurrent
and overvoltage
frequently.
1: The motor parameters are set
improperly.
2: The acceleration/deceleration
time is improper.
7KHORDGÀXFWXDWHV
1: Set the motor parameters
or perform motor auto-tuning
again.
2: Set proper acceleration/
deceleration time.
3: Contact the agent or Inovance
for technical support.
10
Err17 is reported
upon power-on or
running.
The soft startup contactor is not
closed.
1: Check whether the contactor
cable is loose.
2: Check whether the contactor
is faulty.
3: Check whether 24 V power
supply of the contactor is faulty.
4: Contact the agent or Inovance
for technical support.
11
is
displayed upon
power-on.
Related component on the control
board is damaged.
Replace the control board.
efesotomasyon.com
Summary of Contents for MD380 Series
Page 8: ...efesotomasyon com...
Page 9: ...1 Safety Information and Precautions efesotomasyon com...
Page 16: ...Safety Information and Precautions MD380 User Manual 16 efesotomasyon com...
Page 17: ...2 Product Information efesotomasyon com...
Page 28: ...Product Information MD380 User Manual 28 efesotomasyon com...
Page 29: ...3 Mechanical and Electrical Installation efesotomasyon com...
Page 46: ...Mechanical and Electrical Installation MD380 User Manual 46 efesotomasyon com...
Page 47: ...4 Operation Display and Application Examples efesotomasyon com...
Page 82: ...Operation Display and Application Examples MD380 User Manual 82 efesotomasyon com...
Page 83: ...5 Function Code Table efesotomasyon com...
Page 138: ...Function Code Table MD380 User Manual 138 efesotomasyon com...
Page 139: ...6 Description of Function Codes efesotomasyon com...
Page 249: ...7 EMC efesotomasyon com...
Page 261: ...8 Selection and Dimensions efesotomasyon com...
Page 293: ...9 Maintenance and Troubleshooting efesotomasyon com...