Description of Function Codes
MD380 User Manual
- 212 -
Function Code
Parameter Name
Setting Range
Default
FA-15
Proportional gain Kp2
0.0–100.0
20.0
FA-16
Integral time Ti2
0.01–10.00s
2.00s
FA-17
Differential time Td2
0.000–10.000s
0.000s
FA-18
PID parameter switchover
condition
0: No switchover
1: Switchover via DI
2: Automatic switchover
based on deviation
3: Automatic switchover
based on running
frequency
0
FA-19
PID parameter switchover
deviation 1
0.0% to FA-20
20.0%
FA-20
PID parameter switchover
deviation 2
FA-19 to 100.0%
80.0%
In some applications, PID parameters switchover is required when one group of PID
parameters cannot satisfy the requirement of the whole running process.
These parameters are used for switchover between two groups of PID parameters.
Regulator parameters FA-15 to FA-17 are set in the same way as FA-05 to FA-07.
The switchover can be implemented either via a DI terminal or automatically implemented
based on the deviation.
If you select switchover via a DI terminal, the DI must be allocated with function 43 "PID
SDUDPHWHUVZLWFKRYHU,IWKH',LV2))JURXS)$WR)$LVVHOHFWHG,IWKH',LV
21JURXS)$WR)$LVVHOHFWHG
If you select automatic switchover, when the absolute value of the deviation between PID
IHHGEDFNDQG3,'VHWWLQJLVVPDOOHUWKDQWKHYDOXHRI)$JURXSLVVHOHFWHG:KHQWKH
absolute value of the deviation between PID feedback and PID setting is higher than the
YDOXHRI)$JURXSLVVHOHFWHG:KHQWKHGHYLDWLRQLVEHWZHHQ)$DQG)$WKH
PID parameters are the linear interpolated value of the two groups of parameter values.
Figure 6-29 PID parameters switchover
PID deviation
PI
parameters
Group 1 of PID
parameters
FA-19
FA-20
FA-05, FA-06, FA-07
FA-15, FA-16, FA-17
Group 2 of PID
parameters
efesotomasyon.com
Summary of Contents for MD380 Series
Page 8: ...efesotomasyon com...
Page 9: ...1 Safety Information and Precautions efesotomasyon com...
Page 16: ...Safety Information and Precautions MD380 User Manual 16 efesotomasyon com...
Page 17: ...2 Product Information efesotomasyon com...
Page 28: ...Product Information MD380 User Manual 28 efesotomasyon com...
Page 29: ...3 Mechanical and Electrical Installation efesotomasyon com...
Page 46: ...Mechanical and Electrical Installation MD380 User Manual 46 efesotomasyon com...
Page 47: ...4 Operation Display and Application Examples efesotomasyon com...
Page 82: ...Operation Display and Application Examples MD380 User Manual 82 efesotomasyon com...
Page 83: ...5 Function Code Table efesotomasyon com...
Page 138: ...Function Code Table MD380 User Manual 138 efesotomasyon com...
Page 139: ...6 Description of Function Codes efesotomasyon com...
Page 249: ...7 EMC efesotomasyon com...
Page 261: ...8 Selection and Dimensions efesotomasyon com...
Page 293: ...9 Maintenance and Troubleshooting efesotomasyon com...