Group F2: Motor 1 Vector Control Parameters
Group F2 is valid for vector control, and invalid for V/F control.
Function Code
Parameter Name
Setting Range
Default
F2-00
Speed loop proportional gain 1
1–100
30
F2-01
Speed loop integral time 1
0.01–10.00s
0.50s
F2-02
Switchover frequency 1
0.00 to F2-05
5.00 Hz
F2-03
Speed loop proportional gain 2
1–100
20
F2-04
Speed loop integral time 2
0.01–10.00s
1.00s
F2-05
Switchover frequency 2
F2-02 to maximum
frequency
10.00 Hz
Speed loop PI parameters vary with running frequencies of the AC drive.
If the running frequency is less than or equal to "Switchover frequency 1" (F2-02), the
speed loop PI parameters are F2-00 and F2-01.
If the running frequency is equal to or greater than "Switchover frequency 2" (F2-05),
the speed loop PI parameters are F2-03 and F2-04.
If the running frequency is between F2-02 and F2-05, the speed loop PI parameters
are obtained from the linear switchover between the two groups of PI parameters, as
shown in Figure 6-3.
Figure 6-3 Relationship between running frequencies and PI parameters
Frequency
reference
PI
parameters
F2-00
F2-01
F2-03
F2-04
F2-02
F2-05
The speed dynamic response characteristics in vector control can be adjusted by setting the
proportional gain and integral time of the speed regulator.
To achieve a faster system response, increase the proportional gain and reduce the integral
time. Be aware that this may lead to system oscillation.
The recommended adjustment method is as follows:
If the factory setting cannot meet the requirements, make proper adjustment. Increase the
proportional gain first to ensure that the system does not oscillate, and then reduce the
integral time to ensure that the system has quick response and small overshoot.
Note
Improper PI parameter setting may cause too large speed overshoot, and overvoltage fault may
even occur when the overshoot drops.
efesotomasyon.com
Summary of Contents for MD380 Series
Page 8: ...efesotomasyon com...
Page 9: ...1 Safety Information and Precautions efesotomasyon com...
Page 16: ...Safety Information and Precautions MD380 User Manual 16 efesotomasyon com...
Page 17: ...2 Product Information efesotomasyon com...
Page 28: ...Product Information MD380 User Manual 28 efesotomasyon com...
Page 29: ...3 Mechanical and Electrical Installation efesotomasyon com...
Page 46: ...Mechanical and Electrical Installation MD380 User Manual 46 efesotomasyon com...
Page 47: ...4 Operation Display and Application Examples efesotomasyon com...
Page 82: ...Operation Display and Application Examples MD380 User Manual 82 efesotomasyon com...
Page 83: ...5 Function Code Table efesotomasyon com...
Page 138: ...Function Code Table MD380 User Manual 138 efesotomasyon com...
Page 139: ...6 Description of Function Codes efesotomasyon com...
Page 249: ...7 EMC efesotomasyon com...
Page 261: ...8 Selection and Dimensions efesotomasyon com...
Page 293: ...9 Maintenance and Troubleshooting efesotomasyon com...