Function Code Table
MD380 User Manual
- 124 -
Function
Code
Parameter Name
Setting Range
Default
Property
Group A0: Torque Control and Restricting Parameters
A0-00
Speed/Torque
control selection
0: Speed control
1: Torque control
0
ƾ
A0-01
Torque setting source in
torque control
0: Digital setting (A0-03)
1: AI1
2: AI2
3: AI3
4: Pulse reference (DI5)
5: Communication reference
6: MIN (AI1, AI2)
7: MAX (AI1, AI2)
The value 100% of 1 to 7
corresponds to the setting of A0-
03.
0
ƾ
A0-03
Torque digital setting in
torque control
-200.0% to 200.0%
150.0%
ƿ
A0-05
Forward maximum
frequency in torque control
0.00 Hz to maximum frequency
(F0-10)
50.00 Hz
ƿ
A0-06
Reverse maximum
frequency in torque control
0.00 Hz to maximum frequency
(F0-10)
50.00 Hz
ƿ
A0-07
Acceleration time in torque
control
0.00–65000s
0.00s
ƿ
A0-08
Deceleration time in torque
control
0.00–65000s
0.00s
ƿ
efesotomasyon.com
Summary of Contents for MD380 Series
Page 8: ...efesotomasyon com...
Page 9: ...1 Safety Information and Precautions efesotomasyon com...
Page 16: ...Safety Information and Precautions MD380 User Manual 16 efesotomasyon com...
Page 17: ...2 Product Information efesotomasyon com...
Page 28: ...Product Information MD380 User Manual 28 efesotomasyon com...
Page 29: ...3 Mechanical and Electrical Installation efesotomasyon com...
Page 46: ...Mechanical and Electrical Installation MD380 User Manual 46 efesotomasyon com...
Page 47: ...4 Operation Display and Application Examples efesotomasyon com...
Page 82: ...Operation Display and Application Examples MD380 User Manual 82 efesotomasyon com...
Page 83: ...5 Function Code Table efesotomasyon com...
Page 138: ...Function Code Table MD380 User Manual 138 efesotomasyon com...
Page 139: ...6 Description of Function Codes efesotomasyon com...
Page 249: ...7 EMC efesotomasyon com...
Page 261: ...8 Selection and Dimensions efesotomasyon com...
Page 293: ...9 Maintenance and Troubleshooting efesotomasyon com...