Maintenance and
Troubleshooting
MD380 User Manual
- 296 -
9.3 Faults and Solutions
The MD380 provides a total of 24 pieces of fault information and protective functions. After a
fault occurs, the AC drive implements the protection function, and displays the fault code on
the operation panel (if the operation panel is available).
Before contacting Inovance for technical support, you can first determine the fault type,
analyze the causes, and perform troubleshooting according to the following tables. If the
IDXOWFDQQRWEHUHFWL¿HGFRQWDFWWKHDJHQWRU,QRYDQFH
Err22 is the AC drive hardware overcurrent or overvoltage signal. In most situations,
hardware overvoltage fault causes Err22.
Figure 9-1 Solutions to the faults of the MD380
Fault Name
Display
Possible Causes
Solutions
Inverter unit
protection
Err01
1: The output circuit is grounded
or short circuited.
2: The cable between the motor
and the AC drive is too long.
3: The module overheats.
4: The internal connections
become loose.
5:The main control board is faulty.
6: The drive board is faulty.
7: The inverter module is faulty.
1: Eliminate external faults.
2: Install a reactor or an
RXWSXW¿OWHU
&KHFNWKDWWKHDLU¿OWHUDQG
the cooling fan work properly.
4: Connect all cables
properly.
5: Contact the agent or
Inovance for technical
support.
2YHUFXUUHQW
during
acceleration
Err02
1: The output circuit is grounded
or short circuited.
2: Motor auto-tuning is not
performed.
3: The acceleration time is too
short.
4: Customized torque boost or V/F
curve is not appropriate.
5: The voltage is too low.
6: The motor is started during
rotating.
7: A sudden load is added during
acceleration.
8: The AC drive size is small.
1: Eliminate external faults.
2: Perform the motor auto-
tuning.
3: Increase the acceleration
time.
4: Adjust the manual torque
boost or V/F curve.
5: Adjust the voltage to
normal range.
6: Enable the catching a
spinning motor funcion or
start the motor after it stops.
7: Remove the added load.
8: Replace a large drive.
efesotomasyon.com
Summary of Contents for MD380 Series
Page 8: ...efesotomasyon com...
Page 9: ...1 Safety Information and Precautions efesotomasyon com...
Page 16: ...Safety Information and Precautions MD380 User Manual 16 efesotomasyon com...
Page 17: ...2 Product Information efesotomasyon com...
Page 28: ...Product Information MD380 User Manual 28 efesotomasyon com...
Page 29: ...3 Mechanical and Electrical Installation efesotomasyon com...
Page 46: ...Mechanical and Electrical Installation MD380 User Manual 46 efesotomasyon com...
Page 47: ...4 Operation Display and Application Examples efesotomasyon com...
Page 82: ...Operation Display and Application Examples MD380 User Manual 82 efesotomasyon com...
Page 83: ...5 Function Code Table efesotomasyon com...
Page 138: ...Function Code Table MD380 User Manual 138 efesotomasyon com...
Page 139: ...6 Description of Function Codes efesotomasyon com...
Page 249: ...7 EMC efesotomasyon com...
Page 261: ...8 Selection and Dimensions efesotomasyon com...
Page 293: ...9 Maintenance and Troubleshooting efesotomasyon com...