MD380 User Manual Product Information
- 21 -
Item
6SHFL¿FDWLRQV
Standard
functions
2YHUORDGFDSDFLW\
G type: 60s for 150% of the rated current, 3s for 180% of
the rated current
P type: 60s for 120% of the rated current, 3s for 150% of
the rated current
Torque boost
Fixed boost
Customized boost 0.1%–30.0%
V/F curve
Straight-line V/F curve
Multi-point V/F curve
N-power V/F curve (1.2-power, 1.4-power, 1.6-power,
1.8-power, square)
V/F separation
Two types: complete separation; half separation
Ramp mode
Straight-line ramp
S-curve ramp
Four groups of acceleration/deceleration time with the
range of 0.0–6500.0s
DC injection
braking
DC injection braking frequency: 0.00 Hz to maximum
frequency
DC injection braking active time: 0.0–36.0s
DC injection braking level: 0.0%–100.0%
Jog control
Jog frequency range: 0.00–50.00 Hz
Jog acceleration/deceleration time: 0.0–6500.0s
2QERDUGPXOWLSOH
preset speeds
A maximum of 16 speeds are supported by means of the
simple PLC function or control terminals.
2QERDUG3,'
It implements the process closed-loop control system .
Auto voltage
regulation (AVR)
It can keep constant output voltage automatically when the
mains voltage changes.
2YHUYROWDJH
2YHUFXUUHQWVWDOO
control
The current and voltage are limited automatically during
drive running so as to avoid frequent tripping due to
overvoltage/overcurrent.
Fast current limit
It reduces the overcurrent faults to the minimum and
guarantees normal running of the AC drive.
Torque limit and
control
It can limit the torque automatically and prevent frequent
overcurrent tripping during drive running.
Torque control can be implemented in the CLVC mode.
Individualized
functions
High performance
Control of asynchronous motor is implemented through the
high-performance current vector control technology.
Power dip ride
through
The load feedback energy compensates the voltage
reduction at instantaneous power down, enabling the AC
drive to continue running within the short time.
Fast current limit
It helps to avoid frequent overcurrent faults of the AC drive.
9LUWXDO,2V
7KH$&GULYHSURYLGHV¿YHJURXSVRIYLUWXDO','2VWR
implement simple logic control.
Timing control
Time range: 0.0–6500.0 minutes
efesotomasyon.com
Summary of Contents for MD380 Series
Page 8: ...efesotomasyon com...
Page 9: ...1 Safety Information and Precautions efesotomasyon com...
Page 16: ...Safety Information and Precautions MD380 User Manual 16 efesotomasyon com...
Page 17: ...2 Product Information efesotomasyon com...
Page 28: ...Product Information MD380 User Manual 28 efesotomasyon com...
Page 29: ...3 Mechanical and Electrical Installation efesotomasyon com...
Page 46: ...Mechanical and Electrical Installation MD380 User Manual 46 efesotomasyon com...
Page 47: ...4 Operation Display and Application Examples efesotomasyon com...
Page 82: ...Operation Display and Application Examples MD380 User Manual 82 efesotomasyon com...
Page 83: ...5 Function Code Table efesotomasyon com...
Page 138: ...Function Code Table MD380 User Manual 138 efesotomasyon com...
Page 139: ...6 Description of Function Codes efesotomasyon com...
Page 249: ...7 EMC efesotomasyon com...
Page 261: ...8 Selection and Dimensions efesotomasyon com...
Page 293: ...9 Maintenance and Troubleshooting efesotomasyon com...