INOVA AUTOMATION
NICE Series Integrated Elevator Solution
–
N Quick Start-Up Guide V1.0
69
Fd-01
Communication
response delay
0~20
10
ms
Fd-02
Communication
timeout
0.0 ~60.0
0: Invalid
0.0 s
s
Fd-03
Number of elevators in
parallel control mode
1~2
1
-
Fd-04
Elevator No.
1~2
1
-
Fd-05
Parallel control
function selection
Bit 0: Dispersed waiting
1
-
FE - Elevator Display Function Setting
FE-00
Collective selective
mode
0
~
2
0:Full Collective Selective
1:Down Collective
2:Up Collective
0
-
FE-01
Floor 1 display
0000
~
1999
Note: the first two numbers represent tens digit code of the floor;
the last two represent first rank code. The first rank codes are as
Follows:
00: display“0”
01: display“1”
02: display“2”
03: display“3”
04: display“4”
05:
display“5”
06: display“6”
07: display“7”
08: display“8”
09: display“9”
10: display “10”
11: display
”b”
12: display
”G”
13: display
”H”
14: display
”L”
15: display
”n”
16: display
”P”
17: Reserved
18: display “_”
19: no display
23: Display “C”
24: Display
“d”
25: Display “E”
26: Display “F”
28: Display “J”
31: Display “o”
35: Display “U”
Larger than 35: No Display
(End)
1901
-
FE-02
Floor 2 display
1902
-
FE-03
Floor 3 display
1903
-
FE-04
Floor 4 display
1904
-
FE-05
Floor 5 display
1905
-
FE-06
Floor 6 display
1906
-
FE-07
Floor 7 display
1907
-
FE-08
Floor 8 display
1908
-
FE-09
Floor 9 display
1909
-
FE-10
Floor 10 display
0100
-
FE-11
Floor 11 display
0101
-
FE-12
Hall call output
selection
0
~
3
0:7 Segment code
1: BCD code
2: Grey Code
3: Binary code
4: One to one output
0
-
FE-13
Elevator factory
function setting 1
0
~
65535
Select according to bit;
if this bit is 1, the function is enabled
If the bit is 0, the function is disabled
Bit0: Reserved
Bit1: Reserved
00000
b00 0
b01 0
b02 0
b03 0
-