INOVA AUTOMATION
NICE Series Integrated Elevator Solution
–
N Quick Start-Up Guide V1.0
60
Bit 6
Door 1 open limit
Bit 7
Door 2 open limit
Bit 14
Direction Change signal
Bit 15
Independent signal
State of input terminal 3
Bit 0
Door 2 selection
Bit 1
UPS input
Bit 2
Door open button
Bit 3
Door close button
Bit 4
Safety circuit
Bit 5
Door lock circuit 1
Bit 6
Door lock circuit 2
Bit 7
Half load signal
Bit 8
Motor over heat signal
Bit 9
Door 1 safety edge
Bit 10
Door 2 Safety edge
Bit 11
Earthquake signal
Bit 12
Back door forbidden
Bit 13
Half load signal
Bit 14
Single/Double door selection
Bit 15
Fire emergency floor switchover
State of output terminal 1
Bit 0
Reserved
Bit 1
RUN (SW) contactor
Bit 2
Brake (BY) contactor
Bit 3
Higher voltage start-up of brake
Bit 4
Fan/Lamp output
Bit 5
Shorting stator (FX) contactor
output
Bit 6
Door 1 open command
Bit 7
Door 2 open command
Bit 8
Door 2 open command
Bit 9
Door 2 Close command
Bit 10
Low 7 segment ‘a’ display output
Bit 11
Low 7 segment ‘b’ display output
Bit 12
Low 7 segment ‘c’ display output
Bit 13
Low 7 segment ‘d’ display output
Bit 14
Low 7 segment ‘e’ display output
Bit 15
Low 7 segment ‘f’ dis
play output
State of output terminal 2
Bit 0
Low 7 segment ‘g’ display output
Bit 1
Up arrow display output
Bit 2
Down arrow output
Bit 3
Minus sign display output
Bit 4
Returning to base floor at fire
emergency output
Bit 5
Buzzer Output
Bit 6
Overload output
Bit 7
Arrival gong output
Bit 8
Full load output
Bit 9
Inspection output
Bit 10
Fan/Lamp output 2
Bit 11
Door Lock short circuit contactor output
Bit 12
BCD/Grey code/7 segment code high-bit
output
Bit 13
Controller normal running output active
Bit 14
Lift lock output
Bit 15
Reserved
FA-03
Current encoder angle
0.0
~
360.0
000.0
Degree
(°)
●
FA-04
Reserved
-
-
-
-
FA-05
Control Board
Software 3
0
~
65535
0
-
●
FA-06
Drive Board software
0
~
65535
0
-
●
FA-07
Heat sink temperature
0
~
100
0
°C
●
FA-08
Controller Model
1000
-
●
FA-09
Reserved
-
-
-
FA-10
Reserved
-
-
-
FA-11
Pre-torque Current
0.0
–
200.0
0
%
●
FA-12
Logic information
0-65535
0
-
●