INOVA AUTOMATION
NICE Series Integrated Elevator Solution
–
N Quick Start-Up Guide V1.0
53
F6-64
Program control
selection 1
0
–
65535
Bit0: Reserved
Bit1: Soft limit function- When the up slow-down and down
levelling signals are active and the up levelling signal is
inactive, the system considers that the up limit is performed. It
is the same for the down limit signal.
Bit2: Reserved
Bit3: Reserved
Bit4: Opening only one door of opposite (Door 2) doors under
manual control, applicable only when opposite door control
mode is enabled
Bit5: Clearing calls immediately at elevator lock signal is
enabled
Bit6: Reserved
Bit7: Reserved
Bit8: Reserved
Bit9: Disabling reverse floor number clear
Bit10: Reserved
Bit11: Responding to car calls first, then hall calls
Bit12: Reserved
Bit13: Reserved
Bit14: Reserved
Bit15: Reserved
00000
b00 0
b01 0
b02 0
b03 0
b04 0
b05 0
b06 0
b07 0
b08 0
b09 0
b10 0
b11 0
b12 0
b13 0
b14 0
b15 0
-
F6-65
Program control
selection 2
0
–
65535
Bit0: Reserved
Bit1: Reserved
Bit2: Inspection to stop due to slow-down
Bit3: Reserved
Bit4: Buzzer tweet during door open delay time set in Fb-13
Bit5: Reserved
Bit6: Reserved
Bit7: Reserved
Bit8: Door open at elevator lock
Bit9: Display available at elevator lock
Bit10: Reserved
Bit11: Blinking at arrival - The car display blinks when the
elevator arrives at a floor. The blinking advance time is set in
F6-74
Bit12: Reserved
Bit13: Reserved
Bit14: Reserved
Bit15: Reserved
00000
b00 0
b01 0
b02 0
b03 0
b04 0
b05 0
b06 0
b07 0
b08 0
b09 0
b10 0
b11 0
b12 0
b13 0
b14 0
b15 0
-