NICE Series Integrated Elevator Solution
–
N Quick Start-Up Guide V1.0
58
F8-07
Load cell full-load
setting
0
~
255
100
-
F8-08
Load cell input
selection
0
~
2
0: Invalidation
1: MCB digital sampling
2: MCB Analog sampling
0
-
F8-09
Emergency evacuation
speed upon power
failure
0.000
~
F3-11
0.050
m/s
F8-10
Emergency evacuation
selection upon power
failure
0
~
2
0
: Motor isn’t running
1: UPS power running
2: 48V batter power
0
-
F8-11
Brake apply delay
0.200
~
1.500
0.200
s
F8-12
Fire emergency floor 2
0 to F6-00
0
-
F8-13
Anti-nuisance function
Bit0: Disabled
Bit1: Judged by light curtain
Bit 2: Judged by light-load signal
0
-
F9 - Time Parameters
F9-00
Time of returning to
base floor for an idle
elevator
0
~
240
10
Min
F9-01
Fan/Light turn off time
1
~
240
0: Fan and lamp always ON
2
Min
F9-02
Max. floor running
interval
0
~
45
Invalid if smaller than 3s
45
s
F9-03
Accumulative working
time
0
~
65535
0
h
●
F9-04
Reserved
-
-
-
-
F9-05
High byte of running
times
0
~
9999
1 indicating actual running times 10000
0000
-
●
F9-06
Low byte of running
times
0
~
9999
0000
-
●
F9-07
Reserved
-
-
FA - Keyboard Setting Parameters
FA-00
Reserved
-
-
-
FA-01
Running
display
1
~
65535
Bit
Parameter Display
65535
b00 1
b01 1
b02 1
b03 1
b04 1
b05 1
b06 1
b07 1
b08 1
b09 1
b10 1
b11 1
b12 1
-
Bit 0
Running speed
Bit 1
Rated speed
Bit 2
Bus voltage
Bit 3
Output voltage
Bit 4
Output current
Bit 5
Output frequency
Bit 6
Current floor
Bit 7
Current Position
Bit 8
Car load
Bit 9
System state
Bit 10
Pre-torque current (%)
Bit 11
State of input terminal -1
Bit 12
State of input terminal -2
Bit 13
State of input terminal -3