INOVA AUTOMATION
NICE Series Integrated Elevator Solution
–
N Quick Start-Up Guide V1.0
62
FA-16
Bus Voltage
0~999.9
0 V
-
●
FA-17
Present Position
0.00~300.0
0 m
-
●
FA-18
Output Current
0.0~999.9
0 A
-
●
FA-19
Output Frequency
0.00~99.9
0 Hz
-
●
FA-20
Torque Current
0.0~999.9
0 A
-
●
FA-21
Output voltage
0~999.9
0 V
-
●
FA-22
Output torque
0~200.0
0 %
-
●
FA-23
Output power
0.00~99.99
0 KW
-
●
FA-24
Communication
interference
0~65535
-
-
●
FA-25
Encoder interference
0
–
65535
-
-
●
FA-26
Input state 1
0
–
65535
0
-
●
Example Of Input State Display
As shown in the above indication, the LED’s from the right to left are
numbered 1, 2, 3, 4 & 5. For FA-26 to FA-
37, LED’s 5 & 4 show the
function code number and LED 3 shows whether the function valid (1) or invalid (0); each segments of LED’s 2 & 1 (total 16, f
rom 0 to 15
segments) show the states of the 16 functions in this
parameter in addition to LED’s 5, 4 & 3 informations.
The above indication shows display of FA-26: LEDs 5, 4, and 3 show that function 10 (Inspection down) is 1 (Valid); LEDs 1 and 2 show
that besides function 10, functions 4 (RUN contactor feedback), 5 (Brake contactor feedback), 6 (Brake travel switch feedback), 7 (Shorting
PMSM stator contactor feedback), and 8 (Shorting door lock circuit contactor feedback) are valid.
FA-26
Input State 1
0
Reserved
8
Shorting door lock circuit
contactor feedback
●
1
Up levelling signal
9
Inspection signal
2
Down levelling signal
10 Inspection up
3
Door zone signal
11 Inspection down
4
RUN contactor feedback
12 Fire emergency signal
5
Brake contactor feedback
13 Reserved
6
Brake travel switch feedback
14 Elevator lock
7
Shorting PMSM stator contactor
feedback
15 Up limit signal
FA-27
Input state 2
0
Down limit signal
8
Door 1 close limit
●
1
Up slow-down signal
9
Door 2 close limit
2
Down slow-down signal
10 Door machine 1 light curtain