54
F6-66
Program control
selection 3
0
–
65535
Bit0: Reserved
Bit1: Cancelling door open/close command at delay of 1s after
door open/ close limit
Bit2: Not judging door lock state at door close output
Bit3: Door close command is output continuously during
elevator running
Bit4: Returning to base floor for verification at first-time power
on
Bit5: Reserved
Bit6: Reserved
Bit7: Reserved
Bit8: Reserved
Bit9: Reserved
Bit10: Reserved
Bit11: Reserved
Bit12: Reserved
Bit13: Reserved
Bit14: Reserved
Bit15: Reserved
00000
b00 0
b01 0
b02 0
b03 0
b04 0
b05 0
b06 0
b07 0
b08 0
b09 0
b10 0
b11 0
b12 0
b13 0
b14 0
b15 0
-
F6-67
Attendant function
selection
0
–
65535
Bit0: Calls cancelled after entering attendant state for the first
time
Bit1: Not responding to hall calls
–
Hall call blinks inside the
car call button, but doesn’t respond
Bit2: Attendant/Automatic state switchover to enable the
setting of F5-00 (Attendant/Normal switchover time) is valid
Bit3: Elevator door closes function after the attendant presses
the door close button manually.
Bit4: Automatic door close function same as the normal state.
Bit5: Buzzer tweeting at 2.5s intervals in attendant state
Bit6: Continuous buzzer tweeting in attendant state
Bit7: Car call button blinking to prompt the hall call registered
Bit8: Reserved
Bit9: Reserved
Bit10: Reserved
Bit11: Reserved
Bit12: Reserved
Bit13: Reserved
Bit14: Reserved
Bit15: Reserved
00000
b00 0
b01 0
b02 0
b03 0
b04 0
b05 0
b06 0
b07 0
b08 0
b09 0
b10 0
b11 0
b12 0
b13 0
b14 0
b15 0
-