INOVA AUTOMATION
NICE Series Integrated Elevator Solution
–
N Quick Start-Up Guide V1.0
3
2. Product Information
2.1. Connection of peripheral electrical
Devices
Ground
AC input reactor
Electromagnetic
contactor
Molded case circuit
breaker (MCCB) or
earth leakage circuit
breaker (ELCB)
Three-phase AC
power supply
Braking resistor
Noise filter on
input side
To guarantee safety, use an
electromagnetic contactor. Do not
use it to start or stop the controller
because such operation reduces
the service life of the controller.
Select a proper breaker to
resist large in-rush current
that flows into the controller
at power-on.
Use within the allowable
power supply specification of
the controller.
Reliably ground the
motor and the
controller to prevent
electric shock.
Reduce the
electromagnetic
interference on
the input side.
P(+)
BR
Braking
unit
+
-
Motor
MF.K
RUN
STOP
RES
QUICK
PRG
ENTER
RUN
LOCAL/REMOT
FED/REV
TUNE/TC
RPM
%
A
V
Hz
External operation panel
Output
reactor
Ground
Ground
Operation box
Hall display
board
Bottom floor
Top floor
Hall display
board
2
4
5
7
8
6
3
1
Suppress the high order harmonic
to improve the power factor.
NICE1000
new
integrated elevator
controller