Page 14
EN
Chapter 4 Assembly and function
4.3.4 Switching cabinet
Connect the power supply plug on the switching cabinet (2)
to the external power supply (230 V / 50 Hz). The cross-sec-
tion of the supply cable must be at least 2.5 mm
2
. The in-
oBEAM F30 may only be run with an approved FI circuit
breaker (30 mA) RCD type B (30 mA).
The connection must be fused with 16 A. All the necessary
connections and controls for operating the machine are lo-
cated on the switching cabinet. It is firmly screwed to the
frame of the machine.
4.4 Displays, controls and connections
1
2
Description of the displays, controls and
connections
Item
Component
1
Main and emergency stop switch
Green = ON, red = OFF
2
3-pole power supply plug
CEE 230 V / 16 A / 50 Hz.
Supply line: 230 V, 1 PH, 2.5 mm
2
.
3
1
2
Description of the displays, controls and
connections
Item
Component
1
- Pump ON “Start”
- Pump OFF “0”
- Reverse pump “Back”
2
Pump rotation speed.
This rotary knob (potentiometer) is used to ad-
just the pump’s rotation speed
3
Set “D” & “R”: Connection for remote control
Set “HP”: Connection for control cable of
mortar pressure sensor
NOTE
Working with and without remote control.
• When the remote control cable is plugged into the
switching cabinet, the machine is switched on and off
via the green push button at the end of the remote
control cable.
• When operating the machine without remote control,
the dummy plug on the switching cabinet must be
plugged into the remote control socket − otherwise,
the machine will not run.
4.4.1 Pump shaft
The pump shaft is connected to the motor via the drive
shaft and rotates during operation in the pump hopper.
The pump shaft is also connected to the rotor via a plug-in
connection. The pump shaft can be pulled out for cleaning
and maintenance work. Before removing the pump shaft,
switch off the machine and pull out the mains plug.