Chapter 10 Maintenance
9.5 Decommissioning
1. Clean the machine.
2. Remove the remote control cable on the switching cab-
inet and insert the dummy plug.
3. Switch the machine off.
4. Pull out the mains plug.
10 Maintenance
Have the machine inspected once a year by a specialist
workshop. Replace parts which are subject to wear as soon
as the wear limits have been reached. Portable machines,
like the inoBEAM F30, must be subject to an annual elec-
trical inspection according to the implementing regulation
for electrical plant and operating resources (DGUV V3). This
inspection may only be carried out by a qualified electrician
(e.g. electrical engineer, electrical technician, master electri-
cian, senior electrician, foreman electrician or assistant elec-
trician). Electrical specialists work at all INOTEC service cen-
tres, conducting electrical inspections in line with DGUV V3.
To arrange an inspection, call the INOTEC service hotline on
+49 7741 6805 777.
10.1 Safety during maintenance work
!
DANGER
Electrical voltage.
Danger of death due to electric shock.
• Work on the electronic control system may only be per-
formed by a qualified electrician.
• Switch off the machine and pull out the mains plug.
• Secure the machine against unexpectedly being switched
back on.
!
DANGER
Rotating shafts.
Danger of death due to being pulled into the ma-
chine and crushed.
When the motor is running, the pump shaft rotates
in the material hopper!
• Do not reach into the rotating shaft.
• Do not place any objects into the rotating shaft.
!
DANGER
Pressurised conveyor hoses.
Risk of injury and risk of property damage due to
escaping and/or flying material, and/or bursting
conveyor hoses!
• Before disconnecting the conveyor hoses, make sure that
the hoses are depressurised. To do so, check the pressure
indicator on the mortar pressure gauge. The pressure in-
dicator must display 0 bar!
• Before opening the hose coupling, let the inoBEAM F30
run in reverse to reduce any pressure!
• Use only conveyor hoses which, depending on the set
used, are permissible with an operating pressure of 40
bar (set “D” and “R”) or 230 bar (set “HP”), and are in
technically perfect condition (e.g. do not have any cracks
or other external damage!).