Page 15
EN
Chapter 4 Assembly and function
4.4.2 Rotor / stator
The choice of rotor/stator depends on the set chosen (see
scope of delivery, accessories or spare parts and diagrams)
and the planned application.
• Pump set “D”-F30
(rotor/stator D6-3 Eco Gold)
for spray applications (18 l / 40 bar)
Item no. 10041913
• Pump set “R”-F30
(rotor/stator R7-1.5)
for floor levelling compounds (50 l / 15 bar)
Item no. 10043416
• Pump set “HP”-F30
(rotor/stator spray)
for airless spray-on smoothing compounds (8 l / 90 bar)
Item no. 10041888
HIGH
PRESSURE
!
DANGER
Replacing rotor/stator.
Dismantling may only be carried out by
instructed persons.
• Ensure that the machine is depressurised.
The pressure gauge must display 0 bar.
• Do not reach into the rotor when it is in
motion.
• Wear tight-fitting clothes and take pre-
cautions with long hair.
• Wear safety goggles
1. Switch off the pump via the push button
and pull out the mains plug.
2. Pull the plug out of the socket on the
switching cabinet.
3. Loosen the three nuts on the pressure
flange and set it aside.
4. Now replace the rotor/stator.
5. Replace the pressure flange and tighten
the three nuts.
6. Insert the plug into the socket on the
switching cabinet.
4.5 Operating modes
The inoBEAM F30 can be loaded with ready-mixed material
from buckets or the feed pump can be combined, for exam-
ple with the inoMIX S50 continuous mixer.