Page 12
EN
Chapter 4 Assembly and function
4 Assembly and function
4.1 Scope of delivery of inoBEAM F30
The scope of delivery is generated using the components
ordered and can be checked using the delivery note.
inoBEAM F30 basic module (item no. 10041083)
• Frame
• 2 running wheels
• 2 swivel castors
• Plastic material hopper
• Cover for material hopper
• Gear motor
• Switching cabinet
• 3 m connecting cable
• Pump shaft
• Stainless steel pump housing
• Tool set
• Assembly, spray lubricant
• Operating manual
Pump set “D”-F30
for spray applications (18 l / 40 bar)
Item no. 10041913*
Pump set “R”-F30
for floor levelling compounds (50 l / 15 bar)
Item no. 10043416*
Pump set “HP”-F30
for airless spray-on smoothing compounds (8 l / 90 bar)
Item no. 10041888*
________________________________
* Scope of delivery, see accessories
4.2 Functionality
The inoBEAM F30 is used to convey pumpable materials
(mineral or organics products) with a particle size of up
to a maximum of 6 mm. The pump shaft transports the
material to the rotor/stator where the necessary pressure is
built up. The material is pumped to the processing location
by means of mortar hoses. There it is either poured onto
the floor or applied to walls or ceilings with the appropri-
ate spray guns or glue guns.
HIGH
PRESSURE
NOTE
Do not use a gun filter when
applying spray-on filler and similar mate-
rials, as the filter will become blocked.
NOTE
Note the optimum assembly sequence.
1. Push the pump shaft into the pump hopper.
2. Connect the rotor/stator and the suction flange to the
pump shaft.
3. Assemble the pressure flange with the mortar pressure
gauge and hose connection to the rotor/stator and lock
the two (set “D” and “R”) or three (set “HP”) tie rods
in place with the nuts.
4. Connect the mortar hose with the quick-release cou-
pling to the hose connection of the mortar pressure
gauge by closing both cam levers.
5. Assemble the appropriate spray head or one-handed
gun to the end of the mortar hose and connect the air
hose to the spray head.
6. Connect the supply cable to the 230V / 16A “feed
supply” CEE plug.
Functionality with remote control cable
7. Take the dummy plug out of jack for the remote con-
trol cable and insert the remote control cable into the
contact.
8. Connect the remote control cable to the material hose
and the air hose of the compressor by means of adhe-
sive tape or cable ties.
4.3 Components
3
2
1
Description of components
Item
Component
1
Frame with material hopper
incl. pump housing, pump shaft, swivel
castors and wheels
2
Drive unit
3
Switching cabinet