Everest XCR - Product manual |
Wiring and Connections
INGENIA | 2020-10-01 00:04:38
53
Mode
State
STO1
status /
level
STO2
status /
level
Power
stage
status
STO
report
bit
status
STO
abnorm
al fault
State description
Abnor
mal
opera
tion
Abnormal
STO
0
< 1.1 V
1
> 3.6
V
OFF
0
1
If any issue is detected on the
dual-channel STO function
(their state is different for a
long period of time), an
abnormal fault is active can be
reported. This state avoids the
application of torque to the
motor. If this persists for > 1.4 s
~ 3.4 s the STO will lock in
FAULT state. To reset this fault
a power cycle is needed.
1
> 3.6 V
0
< 1.1
V
OFF
0
1
Abnormal
STO
Latched
x
-
x
-
OFF
NOR
(STO1,
STO2)
1
After >1.4 s ~ 3.4 s of abnormal
STO active, the driver will stay
in this state until the power
supply cycle.
Abnormal
Supply
x
x
x
x
OFF
x
x
If a voltage out of the limits is
detected on the internal logic
voltages, the system is
conducted to a safe state,
similar to power-off. Only if the
safe logic voltages are
recovered (usually after
reparation or restart), the
system can return to any other
state.
9.4.5. Interface and Connections
The wiring of the recommended STO circuit is shown next.