8.4.4. CONFIGURATION MENU
Configuration
> Pregaz > 400ms
Postgaz 400ms
Langue FR
Compteurs
Reset machine
Info
Press the left-side + and - keys to move the left cursor (Pre-Gas, Post-Gas, Language, Machine reset and Info.).
When the Pre-gas, Post-gas or language options are highlighted, press the right-side + and - keys to change their value.
Test
Settings range
Comments
Pre-Gas
No Gas between 0.2 - 3 s.
Setting the Pre-Gas time to at least 0.4 s is recommended for gas-
shielded welding.
Post-Gas
No Gas between 0.2 - 3 s.
Setting the Post-Gas time to at least 0.4 s is recommended for wel-
ding under gas shielding.
Languages
FR, EN, DE, NL, ES, IT and
RU.
Press the return button
to go back to the main menu.
8.4.4.1. Resetting the Machine
When ‘Machine Reset’ is selected from the configuration menu, pressing the Menu/Enter button
will bring up the
machine’s reset submenu.
Reset machine
:3sec
pour valider
Hold down the Menu/Enter button
for three seconds to confirm resetting the device.
Press the return button
to go back to the settings menu and to cancel resetting the device.
Resetting the ARCPULL
350 will clear all welding settings from the program menu, switch the product
back to French and the Pre-Gas and Post-Gas times will automatically return to 0.4 s.