58
Operating manual
ARCPULL 350
Translation of the original
instructions
2 - Ignition:
•
Can be adjusted between -2 - +8. This directly affects the device’s power converter setpoint.
• The default value (0) ensures the best possible ignition without the risk of breaking the arc when the attachment is
lifted whilst also limiting the short-circuit current.
• Increase the ignition slightly if the arc repeatedly breaks.
3 - Cleaning: Set the time (in milliseconds) and cleaning current. See section
4
for further details.
4 - Arc: Set the time (in milliseconds) and the arc current. See section 4 for further details.
5 - Attaching:
•
Can be adjusted between -2 - +8. This directly affects the device’s power converter setpoint.
• The default value (0) ensures the best possible attachment of the electrode to the support plate.
6 - Height:
• The consumable’s lift height (in millimetres) during the welding process.
•
If the height is too great, the arc will be extinguished more frequently (see section
5
.7). If the height is too low, the
weld may be short-circuited due to the stud’s tip being warped during the welding process.
Pressing the Menu/Enter button
will confirm the welding settings and return the machine to the MANUAL mode
welding screen.
Press the return button
to discard the settings and return to the main menu.
8.4.3. PROGRAM MENU
Up to 99 different welding configurations, in both SYNERGY and MANUAL mode, can be saved to the machine.
Programmes
> Sauvegarder
Rappeler
Effacer
Effacer tout
Press the left-side + and - keys to move the left cursor and select one of the four functions in the program menu
(Save, Recall, Delete and Delete All).
Pressing the
button opens the highlighted function.
Press the return button
to go back to the main menu.
When a welding configuration is saved or recalled, «Prog» followed by the program number is displayed on the wel
-
ding screen (in both SYNERGY and MANUAL mode).