45
Cinemage User Manual
Version 4.1.x ©2010
Adjust the backlight to a comfortable setting for your ambient environment using the
trackball. Press the Read CIE xyY button:
↑
Read the “Y” result under CIE xyY, and adjust the backlight either up or down until the
desired luminance output is reached, pressing the Read CIE xyY button to display new
readings. Once desired luminance is reached, press the Back button twice to return to
Display Setup menu:
↑
(x2)
Select Monitor Profiling:
↑
Select Auto Profile Display and follow the on screen instructions:
↑
Check the results against the target located in the menu bar:
↑
Make adjustments to the backlight for Luminance level and Manual Calibration settings
as needed and re-calibrate until you have the desired results.
Back
Target: x=.314, y=.345
Read CIE xy,Y
x=.314, y=.345, Y=115Cd
Read CIE X,Y,Y
X=.314, Y=.345, Y=115 Cd
Select Calibration
Video Source
Set Flat
Field
Backlight Brightness
20.0%
Back
Target: x=.314, y=.345
Read CIE xy,Y
x=.314, y=.345, Y=115Cd
Read CIE X,Y,Y
X=.314, Y=.345, Y=115 Cd
Select Calibration
Video Source
Set Flat
Field
Backlight Brightness
450
Back
Video Setup
Calibration
Setting:
Monitor
Profiling
More Display
Setup
Backlight Brightness
Back
Auto Profile
Display
Change Sample
Count
Profile Options
Manage
Profiles
Reset Probe:
Back
Target: x=.314 y=.345
Auto Profile
Display
Change Sample
Count
Profile Options
Manage
Profiles
Reset Probe: