Draco MultiView 4K
60
Configuration via OSD
71
Field
Entry
Description
Lock Monitor EDID
Y
Lock the current monitor EDID in the configuration.
After switching on, restarting, or reconnecting during operation,
the locked EDID will be used from the source instead of the
native EDID of a future connected monitor.
N
After switching on, restarting, or reconnecting during operation,
the video signal is displayed with the resolution of the preset
default EDID (see chapter 6.4.1, page 84).
Audio Mixing
Y
Merge incoming audio streams into a single stereo stream.
Depending on the device type, up to 8 audio streams (7.1) can
be merged into a 2-channel stereo stream.
N
Function not active (default).
Enable MSC
Y
Enable the Multi-Screen Control.
Absolute mouse coordinates are used for the MSC automatic
mode with/without restriction (see chapter 9, page 141).
Moving the mouse pointer over the edge of one window into
another window, the USB-HID control switches seamlessly to
the associated input.
N
Function not active (default).
Relative mouse coordinates are used.
For Dual-Head installations, MSC is recommended to be only
activated if using the Hot Mouse function in PiP Mode and
Preview Mode. The behavior of the mouse movement in Dual-
Head systems has to be noticed (see chapter 9, page 141).
Enable Hot Mouse
Y
Enable Hot Mouse function (enabled MSC function is required)
Moving the mouse pointer over the edge of one window into
another window, in PiP Mode and Preview Mode, turns the Hot
Mouse Mode on. A transparent overlay, and an overlay mouse
pointer (OSD mouse) appear. The OSD mouse can be used to
activate another source by clicking in the respective window.
For Dual-Head installations, the Hot Mouse function is only
recommended in PiP Mode and Preview Mode. The behavior of
the mouse movement in Dual-Head systems has to be noticed
N
Function not active (default).
Default Display Mode
List
Start the Draco MV after a switch-on or a restart with the default
display mode.