SNMP Trap
The SNMP agent must be activated to activate the SNMP traps.
Traps
Description
Enable Traps
Sending of trap messages from the SNMP agent to the SNMP server.
Server Address
IP address of the SNMP server in the form “192.168.1.1” and of the SNMP port
(default: 162).
Status
Notification about the Draco MV status.
Power Supply #1
Notification about the status of power supply unit #1.
Power Supply #2
Notification about the status of power supply unit #2.
Switch Command
Notification about a performed switching operation at the Draco MV.
Insert Output
•
Notification about a newly connected console to the Draco MV.
•
Notification about a switched-on console.
Remove Output
•
Notification about a removed console from the Draco MV.
•
Notification about a switched-off console.
Input Video Info
Notification about a change of resolution or change of frequency.
EDID Change
Notification about a change in EDID information at the inputs.
Activating the SNMP Agent
To activate the SNMP agent, proceed as follows:
1. Select
Configuration > SNMP
in the main menu.
2. Set the
Enable
option to
Y
(Yes) within
SNMP Agent
.
By activating this option, the permission for an active query of the SNMP agent is granted.
Activate SNMP Traps
To activate SNMP traps, proceed as follows:
1. Set the
Enable Traps
option to
Y
(Yes) within
SNMP Server
.
This function allows an active transmission of trap messages from the SNMP agent to the SNMP
server.
2. Set the IP address of the SNMP server within
Server Address
.
3. Set the requested traps to
Y
(Yes) to enable them.