SmartPLC SafeLine with PROFIBUS slave interface
40
Device type SLG-2
42203
Circuit diagram/wiring diagram
Description
Safety classification
max. SIL max. PL max. cat.
Safety light grids type 4
Self-testing with 2 OSSD outputs (test
signals are generated by the sensor and
filtered or ignored by AC412S
Examples (ifm art. no.):
– OY114S to OY116S
– OY901S to OY903S
– OY421S to OY423S
– OY120S to OY122S
– OY951S to OY953S
3
e
--
► Note the supply voltage limits of the safety light grid.
► Select the input circuits according to the max. safety classification (SIL / cat. / PL).
When the indicated ifm articles are used, the maximum safety classification according to the
SIL/Cat./PL values listed in the table can be achieved. Note the current standards.
► If other than the indicated products are used, note the current standards.
► Test the safety function within the two-error occurrence time.
The second-error occurrence time takes 24 hours. Within this time the safety function of
the device should be requested once.