background image

SYRIS 

SY120SA-V5EM  SY120SA-V5M1 

Operation Manual 

 

SYRIS Technology Corp.

   

12F, NO.12, Sec1, Taijunggang Rd, Taichung , Taiwan (403)     
Tel 

 +886-4-2207-8888 

Fax

886-4-2207-9999 

Email

[email protected]

 

web

 

http://www.syris.com

       

   

 

Ver: 03.24

 

Summary of Contents for SY120SA-V5EM

Page 1: ...120SA V5EM SY120SA V5M1 Operation Manual SYRIS Technology Corp 12F NO 12 Sec1 Taijunggang Rd Taichung Taiwan 403 Tel 886 4 2207 8888 Fax 886 4 2207 9999 Email service syris com web http www syris com Ver 03 24 ...

Page 2: ...System DO Function Setup this function needs to operate under login status 6 7 System Group and Timer Control Function Operation this function needs to operate under login status 6 8 Set up card number and password open door way 8 this function nneds tooperateunder login status 8 9 System default 9 10 Steal Alarm System Function Setup 9 11 Anti Force Function Setup 10 12 Expand Function Set up 10 ...

Page 3: ...alter the three set password before using and avoid the unconcerned personnel to login system the password alter method as following Use preset password 1234 login and enter FUN 4 1 NNNN NNNN EN NNNN new password enter second time as confirm action Then enter FUN 2 EN to logout system to complete the first group password wetting The second and third password as the above procedure repeat use prese...

Page 4: ... Enter FUN 3 5 NNNN G EN and proximity card one by one NNNN assign card serial numbers from 0001 2000 G assign card group number range 1 4 Example add five card from sequent number 0002 and set to group1 FUN 3 5 0 0 0 2 1 EN proximity five un use cards The sequent number will automatically edit 0002 to 0006 the group all set to1 3 Delete Card Operation Procedure this function needs to operate unde...

Page 5: ...ple modify the original card sequent number 0001 in group 1 to group 2 FUN 3 3 0 0 0 1 2 EN 4 2 Modify One Card Enter FUN 3 4 NNNN S EN NNNN assign the card number which want to modify the card status rnage 0001 2000 S S 1 set up card enable S 0 set up card disable Example disable the sequent number 0002 card FUN 3 4 0 0 0 2 0 EN restart the sequent number 0002 card FUN 3 4 0 0 0 2 1 EN 4 3 Modify...

Page 6: ... to set up range 1 8 K 5 as SY120SA CALL key K 6 as expandkeypad reader CALL key K 7 as expandDI 1 K 8 as expandDI 2 F DI purpose number please refer the below DI purpose table J 0 for set to NO default 1 for set to NC DI Purpose Table Number Purpose Notation 0 Not use 1 Door detect DI1 preset 2 Open door button DI2 preset 3 Emergency open door button Open door and send out alarm until relief 4 St...

Page 7: ...s relay DO for 2seconds DO Purpose Table Numbe r Purpose Notation 0 Not use 1 Open door control electric lock DO preset 2 Doorbell contact output relay DO preset 3 Burglar alarm output Deploy and withdraw controlled 4 Alarm contact output Use withdraw to cancel alarm 5 Anti force contact output Use FUN 4 4 to cancel anti force alarm Action time set 0 for keeps action until relief Example set up ex...

Page 8: ... up timer from 8am to 6pm FUN 8 2 0800 1800 EN 7 3 group timer set uo passage way setup Enter FUN 8 3 G D N A EN G group number 1 4 D in timer 0 3 N out of timer 0 3 A door passage 1 pass enable preset 0 pass disable In and out of timer function table 0 Can not pass 1 Card or password 2 Card system default 3 Card and password Example Set up group 1 to use card and password for passage in the timer...

Page 9: ... open door Example if already set up card or password opne door then st up card number and password opendoor FUN 5 1 1 EN now before use password to open the door it requires to enter the card number with password For example first enter the user s card number then enter the default password number to open the door 0 0 0 1 0 0 0 0 EN 8 2 alter user preset password default define 0000 Enter FUN 5 2...

Page 10: ...hange from 5678 to 2468 Enter0 0 0 1 5 6 7 8 2 4 6 8 2 4 6 8 EN The card passowrd change from 6578 to 2468 9 System default 9 1 Clear all setting and restore to default including card data parameters and I O data etc Under login status enter FUN 4 9 EN it will response the correct status if correct then enter FUN 4 9 EN again and wait for ten seconds to clear all setting and restore to default 10 ...

Page 11: ...larm E 0 cancel anti force alarm default Example enter anti force password to start the DO which we choose relay DO default Anti force password start using FUN 4 3 G 5 5 5 5 EN Execute anti force alarmFUN 4 4 1 EN DO FUN 7 1 2 5 0 0 3 EN 12 Expand Function Set up 12 1 Expand module Setup Enter FUN 5 7 E EN E 1 has external expand module E 0 no external expand module default 12 2 Expand Card Reader...

Page 12: ...SY120SA SINGLE DOOR CONTROLLER 11 14 SY120SA and Other SY120SA Wiring Diagram 15 SY120SA and MD120EXT 1S Wiring Diagram ...

Page 13: ...EPER CPU M7 M2 LED Orange 橙色 BEEPER Yellow 黃色 D1 White 白色 V Red 紅色 GND Black 黑色 D0 Green 綠色 D0 White 白色 D1 Brown 棕色 BEEPER Violet 紫色 LED Green 綠色 Lock Brown 棕色 Lock Orange 橙色 NC Green 綠色 COM Blue 藍色 NO Violet 紫色 4R Green 綠色 8 15V Red 紅色 GND Black 黑色 4R Yellow 黃色 M5 M4 M6 Ex Door Sensor 門位偵測 Ex Push Button 開門按鈕 NO NC JP1 E Lock Setting FAIL SECURE 送電開門 FAIL SAFE 斷電開門 NO NC RELAY 繼電器 POWER RS485 電源與...

Page 14: ...atus 55 Setup alarm enabled 85 Setup Holiday access limit 56 Setup doorbell enabled 86 Automatic door Setting 41 Modify Master card password 57 Setup extend module 91 Setup controller ID 17 2 Reader LED status list Show light sound Footnote code Status description OK LED SY120SA Power LED SY120SA Error LED error BEEPER voice 0 Normal status off LED Red LED Orange no action 1 Correct status LED Gre...

Page 15: ...E 0 cancel door time out default E 1 enabled door time out alarm TT Time Out time setting Range 01 99 default 20 unit sec 17 6 Enabled or Disable Encryption Card V3 0 Enter FUN 4 8 E EN E E 0 EM TEMIC Card default E 1 Use SYRIS Encryption Card E 2 Use Security Encryption Card 17 7 Error psaaword keylock setting Enter FUN 5 3 K L A EN K setting acceptable error times range 1 9 default 6 L enter loc...

Page 16: ... normal ststus and anti duress alarm will be initiated automatically NNNN valid card number are in the range between 0001 2000 pppp anti duress password The password is four digit If anti duress password personal password are the same the personal password will be the first priority to be checked and the alarm won t be triggered 17 14 Notice 1 While change Master card s password one needs to chang...

Reviews: