SmartPLC SafeLine with PROFIBUS slave interface
122
Configuration status: Colour codes + symbols
42208
Symbol
Colour
Description
yellow
No safe configuration available
green
safe configuration available
>
Diagnostic data: Colour codes + symbols
42229
Symbol
Colour
Description
white
No safe AS-i input slave present
grey
Safe AS-i input slaves present but not part of the safe configuration
green
Safe AS-i input slave operates correctly; no test necessary
yellow
Test requested
red
Error
- no safe AS-i input slave connected
- AS-i slave missing
- AS-i slave present but master in the protected mode and slave not projected
- logical device of the AS-i slave in the error state
- logical device of the AS-i slave in the hardware error state
- invalid or double code sequence
Logical devices are elements of the CODESYS programming system. They are used for the
logical preprocessing of input signals.
For detailed information:
→ Programming manual fail-safe SmartPLC AC4S
For detailed information regarding the error causes:
→
Online Support Centre (OSC)
(
>
Optional: change settings of the safe AS-i input slaves
42322
To change the settings of the selected safe AS-i input slaves:
►
Use the arrow keys to mark the safe AS-i input slave.
►
Use [Select] to activate the marked AS-i slave.
>
Setting options of the selected safe AS-i input slave are displayed.
►
Change the settings as requested.
For information about the settings of the safe AS-i slaves:
→
AS-i 1 / AS-i 2: AS-i slaves
(
►
Use [Back] to return to the display of the diagnostic data.