IER 567 Counter Top Printer – Level 1 Maintenance Manual
N00272A
Page 2-13
Revision Level 2
Nov. 28, 2005
Ce document est la propriété de IER et ne doit pas être reproduit ou communiqué sans autorisation écrite
This document is the property of IER and may not be reproduced or communicated without prior written authorization
f) Hit
Esc
to stop the motor.
NOTE: The test procedure is the same for the solenoids, LEDs and buzzer.
10) Testing the Thermal Printhead
a) Select
the
Head temperature
item using the two arrow keys
▲
▼
.
T e s t s
T e s t m o n i t o r
Æ
H e a d t e m p e r a t u r e
B a d h e a d d o t s
b) Hit
Enter
to confirm. The following message is displayed:
H e a d t e m p e r a t u r e
x x x o C
where
XXX
is the temperature in °C
c) Hit
Esc
to stop the test.
11) Testing the Number of Failed Printhead Heating Elements
a) Select
the
Bad head dots
item using the two arrow keys
▲
▼
.
T e s t s
T e s t m o n i t o r
H e a d t e m p e r a t u r e
Æ
B a d h e a d d o t s
b) Hit
Enter
to confirm. The following message is displayed:
B a d
h e a d
d o t s
x x x
where XXX is the number of failed heating elements
c) Hit
Enter
to stop the test.