9
9. System Wiring for Typical Application
9-1
. Power Connection
- Connect (+) wire of DC +12V power to Red wire and Red/White banded wire.
- Connect Power GND (-) wire of DC +12V to Black wire and Black/White banded wire.
9-2
. Door Lock Connection
9-2-1 Connection of
POWER FAIL SAFE: Door Lock
- Connect Door RELAY (NC), Blue/White banded wire to DC +12V (be sure that the existing
power supply has enough capacity to support this accessory or upgrade to a sufficient one.)
- Connect (+) wire of Door Lock to Door RELAY (COM), Grey/Red banded wire.
- Connect (-) wire of Door Lock to Power GND (-) wire.
9-2-2 Connection of
POWER FAIL SECURE: Door Lock
- Connect Door RELAY (COM), Grey/Red banded wire to DC +12V (be sure that the existing
power supply has enough capacity to support this accessory or upgrade to a sufficient one.)
- Connect (+) wire of Door Lock to Door RELAY (NO), White/Red banded wire.
- Connect (-) wire of Door Lock to Power GND (-) wire.
9-3
. Alarm Device Connection
- Connect Alarm RELAY (COM), White wire to DC +12V (be sure that the existing power supply
has enough capacity to support this accessory or upgrade to a sufficient one.)
- Connect (+) wire of Alarm Device to Alarm RELAY (NO), Purple wire.
- Connect (-) wire of Alarm Device to Power GND (-) wire.