31
●
If the problem still persists, contact our customer service center.
[Communication]
●
Problem
Although the 100R connects with PC, communication was not at all.
●
Cause
▶
Setup malfunction of communication environment
▶
Connection malfunction of communication cable
▶
System malfunction/data damaged or lost due to an external noise or a short circuit.
●
Solution
▶
Make sure that communication environment is set and cables are connected.
☞
Make sure of set up between controller and PC.
1. Make sure that each COM Port is same. COM Port is connected with PC and its
settings should be identically set on application software.
2. Baud rate is fixed by 9600bps. Make sure that communication environment of
application
software is set up as shown below.
☞
Make sure of connecting communication cables.
1. Make sure that connecting communication cables between the 100R and the PC.
2. Make sure of cable’s maximum distance.
- RS232: Max.15m
●
If the problem still persists, contact our customer service center.
[Keypad]
●
Problem
An RF card works properly but the 100R will not recognize the RF card number when it is
entered in the keypad.
●
Cause
▶
An error in system settings
▶
Connection malfunction of communication cable
▶
System malfunction/data damaged or lost due to an external noise or a short circuit.
Make sure to consult a technician before separating or initializing
a product.
Caution
The max transmission range for each communication type is greatly affected
by the communication environment. Eliminate any electrical noise around the
communication cable or disconnect it from other cables.
Caution