![IDTECK Star 100R User Manual Download Page 24](http://html2.mh-extra.com/html/idteck/star-100r/star-100r_user-manual_3763547024.webp)
24
12-81. Set Door Open Time-out for Door Contact Sensor
(tt=00~99 sec., Defaulted value = 00 sec. means no detect Door
Contact Sensor, refer to 12.24 for Alarm time settings)
Configuration Card Command
Door Open time-out
/Configuration PIN
12-82. Set Number of Times of Try-Out
(NN=00~99 times, Defaulted Try-out numbers= 05 times)
Configuration Card
Command
Try-out numbers
/Configuration PIN
12-83. Set Input Keypress Time-out Time
(
tt
=10~99 sec., Defaulted Keypress time-out= 20 sec.,
Minimum
tt
= 10 sec.)
Configuration Card
Command
Keypress time-out time
/Configuration PIN
12-84. Set Tamper Alarm Output Port
(Refer to Table 1 for OM, Defaulted Output port= 02 Alarm Relay)
Configuration Card
Command
Alarm Output Port
/Configuration PIN
12-88. Enable Tamper Alarm
To comply with UL 294, the Standard for Access Control System Units, the Tamper Alarm must
be enabled.
Configuration Card
/Configuration PIN
12-89. Disable Tamper Alarm
Configuration Card
/Configuration PIN
(Defaulted setting)
12-99. Re-Initialize and Erase All Setup Data
Please use this command when you really want to erase all data and start the unit from the
beginning.
Configuration Card
/Configuration PIN
Summary of Contents for Star 100R
Page 1: ...User s Manual...
Page 39: ...39 17 Template...