10
9-4
. Exit Button Connection
- Connect one of the wires of Exit Button to Exit Button Input, Yellow/Red banded wire.
- Connect the other wire of Exit Button to Power GND (-) wire.
(If a normally closed Exit button is used, then see section 12-67 to change the detection
scheme from the defaulted setting)
9-5
. Door Contact Sensor Connection
- Connect Door Contact sensor (COM) wire to Door Contact Input, Green wire.
- Connect Door Contact sensor (NO) wire to Power GND (-) wire.
(If a normally closed Door Contact sensor is used, then see section 12-69 to change the
detection scheme from the defaulted setting.)
9-6
. Auxiliary
Input Device Connection
(Applied to AUX Input #1, #2, #3)
- Connect one wire of the Auxiliary Input Device to the AUX Input wire
(Input #1 Orange, Input #2 Green/White banded, Input #3 Brown wire).
- Connect the other wire of Auxiliary Input Device to Power GND (-) wire.
(If a normally closed input device is used, then see section 12-61,63 & 65 to change the
detection schemes from the defaulted settings.)
9-7
. Auto-Dialer Connection
(Separate purchase required)
The Auto-dialer function of this unit has not been evaluated by UL.
- Connect the input wire of Auto-Dialer to TTL output, Orange/White banded wire.
- Connect (+) wire of Auto-Dialer to DC +12V (be sure that the existing power supply has
enough capacity to support this accessory or upgrade to a sufficient one.)
- Connect (-) wire of Auto-Dialer to Power GND (-) wire.
- Connect Telephone Line plug (RJ-14) to Auto-Dialer.
(
If an active High Auto-Dialer is used, then see section 12-71 to change the TTL output level
from the defaulted setting.)
9-8
. Wiegand Input Connection From Another Compatible Wiegand Reader
(Separate purchase required)
- Connect (+) wire of Reader to DC +12V (be sure that the existing power supply has enough
capacity to support this accessory or upgrade to a sufficient one.)
- Connect (-) wire of Reader to Power GND (-) wire.
- Connect Wiegand output DATA0 wire of the additional Reader to DATA0, Pink wire.
- Connect Wiegand output DATA1 wire of the additional Reader to DATA1, Cyan wire.
9-9. RS-232 Communication Port Connection
9-pin connector (COM Port, female) is required to connect serial communication RS-232
between Main Unit and Personal Computer.
- Connect RS-232-TX, Grey wire of Main Unit to pin number 2 of 9-pin connector.
Summary of Contents for Star 100R