7-2. Using 2 screws, install wall mount to the wall.
※
CAUTIONS
Before mounting the STAR 100R unit to the Wall Mount bracket, operational testing of the
unit should be completed, as the locking pins will lock the unit to the Wall Mount. Removing
the unit from the Wall Mount bracket after they have been installed together may cause
damages to the bracket and render its effectiveness.
7-3. Insert 5 O-rings to the wall mount as indicated, then route the cable of the main unit through
the center hole and push the main unit to wall mount to lock the main unit and make sure
that the main unit is locked with wall mount.
8. Wiring Color Table
SIGNAL
COLOR
Main Power (+12V)
Red
Power Ground (GND)
Black
Door Relay Out (COM)
Gray with Red stripe
Door Relay Out (NC)
Blue with White stripe
Door Relay Out (NO)
White with Red stripe
Alarm Relay Out (COM)
White
Alarm Relay Out (NC)
Purple with White stripe
Alarm Relay Out (NO)
Purple
TTL Out
Orange with White stripe
Chime Bell Out
Brown with White stripe
Wiegand Data 0 In
Pink
Wiegand Data 1 In
Cyan
Exit Button In
Yellow with Red stripe
Door Contact In
Green
Aux In 1
Orange
Aux In 2
Green with White stripe
Aux In 3
Brown
RS232 (TX)
Gray
RS232 (RX)
Blue
RS232 (GND)
Yellow