15
11-7. Chime Bell Operation
The key can be used to activate an external Chime Bell for 5 seconds, the defaulted value.
12. Setting Changes
Configuration Card/PIN is required to change existing or defaulted setting values or to manage user’s
access. First, present the Configuration Card (or enter the Configuration PIN) and enter the 2-digit
command code.
RF Only Mode or RF + PIN Mode
PIN
Only
Mode
+
or
+
Configuration Card Command Code
Configuration PIN Command
Code
Summary Table of Commands
Command Action/Change setting values
11
Add User Access Cards (RF CARD ONLY MODE)
12
Add User Access Cards and PIN (RF CARD + PIN MODE)
13
Add User Access PIN numbers (PIN ONLY MODE)
14
Delete User Access Cards (or PIN)
15
Add User Access Card/PIN (RF/PIN Combination Mode)
21
Change Door open time when User Access Card (or PIN) is granted
22
Change Alarm time when User Access Card (or PIN) is denied
23
Change Alarm time when Try-Out error detected
24
Change Alarm time when Door-Contact error detected
25
Change Alarm time when Aux Input #1 detected
26
Change Alarm time when Aux Input #2 detected
27
Change Alarm time when Aux Input #3 detected
28
Change Alarm time when magnet detected
29
Register 2 digits Duress Alarm password
30
Change Alarm time when Duress Alarm detected
31
Test Door open time set by command "21"
32
Test Alarm time set by command "22"
33
Test Alarm time set by command "23"
34
Test Alarm time set by command "24"
35
Test Alarm time set by command "25"