NOTE: On all installations a battery cut out board should be used. This will cut the battery at 10.5V
protecting the battery and the system. When AC is restored the battery cut out will reset allowing
the battery to be charged.
Keypad
The keypad has a 3V LED output which mimics the armed LED. I.e. when
the system is armed the LED will come on. If a zone violates and an alarm
condition is registered the LED will flash as the armed LED will do.
There is a panic connection for a panic button and no end of line resistor is
necessary.
Note: Due to no EOL resistor please test frequently
Zones
Devices that are connected to zones are divided into two categories, normally open (NO) or
normaly closed (NC). Some devices have both and the installer can select either, depending on
their preference.
Figure 1: Normally Open
Normally open as seen in the figure, is like a switch that by default is always off
and no electricity can flow through it.
Figure 2: Normally Closed
Normally closed, is like a switch that is by default always on and electricity will
flow through it.
Device
Power Consumption
LED Keypad
90mA
Receiver
115mA
Make sure that when connecting the keypad bus
that Data on the keypad is connected to D on the
805 and the same with CK, that it is connected to C.
Keypad Connector
Keypad Connector
Keypad Connector