Location 9: Entry / Exit Options
This location changes the way the alarm reacts when the alarm needs to be armed. If any of the options
below are chosen and are not met, the alarm will not be ready to arm.
Value Entry / Exit
zones must be
clear
Follower
zones must
be clear
Entry / Exit
delay
enabled
Explanation
0 - 7
Instant Arm and all zones must not be violated
8
Off
Off
On
All entry exit and follower zones can be
open and the entry / exit delay is
operational.
9
On
Off
On
Entry exit zones must be closed,
followers can be open and the entry /
exit delay is operational.
10
Off
On
On
Entry / exits can be open, followers
must be closed and the entry exit delay
is operational
11
On
On
On
All zones must be closed and the entry /
exit delay is operational
12
Off
Off
On
All entry exit and follower zones can be
open and the entry / exit delay is
operational.
13
On
Off
On
Entry exit zones must be closed,
followers can be open and the entry /
exit delay is operational.
14
Off
On
On
Entry / exits can be open, followers
must be closed and the entry exit delay
is operational
15
On
On
On
All zones must be closed and the entry /
exit delay is operational
Location 10: Secondary Entry Delay
This is the time the alarm will allow between the secondary entry zone, being opened and a valid user
code being entered, before the alarm is activated.
Value Delay Value Delay
0
0.25
8
4
1
10
9
5
2
20
10
10
3
30
11
15
4
45
12
18
5
1
13
21
6
2
14
24
7
3
15
27