Location 1 to 8: Zone Types
A zone type is how a zone acts when the alarm is armed or disarmed. A value is associated with each
zone type and when entered into the zones location it changes that zone to the type it represents.
Value Type
Explanation
0
Disable
It is suggested that a 3k3 resistor is placed across the zone
1
Entry / Exit
An entry/exit zone is a zone that allows entry into the building when
the alarm is armed and allows the exiting of the building during
arming
2
Follower
A follower zone is disabled during arming until the system is armed,
then once armed the zone is active and will violate as soon as a
violation occurs. When the system is armed and an entry / exit zone is
triggered a follower zone is disabled, until a valid user code is
entered, if not then it will become active again.
3
Audible
Priority
Regardless of whether the panel is armed or not, a violation of an
Audible Priority zone will cause the control panel to register an alarm
condition and sound the siren.
4
Audible
Instant
If the panel is armed, the violation of an instant zone will cause the
control panel to immediately register an alarm condition and sound
the siren.
5
Arm /
Disarm
A violation of an Arm/ Disarm zone will cause the panel to arm or
disarm depending on its current state. The end-of-line resistor is
required.
6
Silent
Priority
Regardless of whether the panel is armed or not, violation of a Silent
Priority zone will not cause the siren to sound but will report the
appropriate code programmed into the relevant locations to the
central station.
7
Silent
Instant
If the panel is armed the violation of a Silent Instant zone will cause
the control panel to immediately register an alarm condition but the
siren will not sound
8
Secondary
Entry / Exit
A secondary entry/exit zone is the zone that allows entry into the
building when the alarm is armed and allows the exiting of the
building during arming.
10
Fire Zone
Violation of a Fire zone will cause the siren to sound regardless of
whether the panel is armed or not. The siren will sound intermittently
(one second on, one second off
12
Push to
Arm
If the entry / exit is set to 21 minutes; once the exit delay has
commenced, a violation of the push to arm zone will immediately arm
the panel
Default values in locations 1 to 8. Each location is assigned to a zone.
Zone Value Loc Discription
1
1
1
Entry / Exit
2
2
2
Follower
3
4
3
Instant
4
4
4
Instant
5
4
5
Instant
6
4
6
Instant
7
4
7
Instant
8
3
8
Panic