Location 18: Exit Delay Period
This is the time a person has from entering their code or using the quick arm key, [1], to exiting the
building through the entry exit zones, without setting the alarm off.
Location 19: AC Fail and Restore Time
This is the time the alarm system waits for the AC to be off or back on, before it reports back to the alarm
monitoring company. The trouble light will begin to flash immediately.
Value Time-
out
Value Time-
out
0
1 min
8
9 min
1
2 min
9
10 min
2
3 min
10
11 min
3
4 min
11
12 min
4
5 min
12
13 min
5
6 min
13
14 min
6
7 min
14
15 min
7
8 min
15
16 min
Location 20: Primary Entry Delay
The time period from opening a primary entry / exit zone to a person having to entering a valid user code,
before the alarm is triggered.
Location 21: Hardware Reset Switch Enable / Disable
If this option is enabled the alarm system cannot be defaulted via the hardware default button. The only
way to default would be via the installer code and location 0.
Note: Please make sure the installer code is changed and correct before enabling this option.
Value Action
10
Disable
15
Enable
Value Time-out Value
Time-out
Value Time-
out
0
0.25 sec
6
2 min
12
18 min
1
10 sec
7
3 min
13
21 min
2
20 sec
8
4 min
14
21 min
3
30 sec
9
5 min
15
21 min
4
45 sec
10
10 min
5
1 min
11
15 min
Value Time-out Value Time-
out
0
0.25 sec
8
4 min
1
10 sec
9
5 min
2
20 sec
10
10 min
3
30 sec
11
15 min
4
45 sec
12
18 min
5
1 min
13
21 min
6
2 min
14
21 min
7
3 min
15
21 min