IDS 805 Training Manual Download Page 1

 

 

 

 

 

 

 

 

 

 

 
 
 
 

 

Installer Training 

805 Stock Code: 860-1-B08-MN 
805S Stock Code: 860-1-0808M 

 

 

 

 

 

 

 
 

 

 

 

 
 

 

Training Manual 

s

 

Summary of Contents for 805

Page 1: ...Installer Training 805 Stock Code 860 1 B08 MN 805S Stock Code 860 1 0808M Training Manual s...

Page 2: ...______________________________________________ 29 Adding General User Codes _________________________________________________________________________ 29 Adding a Maid s Code___________________________...

Page 3: ...ry retains all program and event log data in the event of a total power failure Programmable loop response time for all zones global Up and downloadable using IDS windows based software Excellent prot...

Page 4: ...Hardware Default Button Dialler Board Connectors Radio Tx Programmable Output 12V Keypad 16V AC Siren Neg Zones Connectors Serial Connector IDS 805 IDS 805s...

Page 5: ...s exceeded this will take current away from the battery charging circuit and the battery may never fully charge Power supply to any radio transmitter While it may seem unnecessary to some in order to...

Page 6: ...stor please test frequently Zones Devices that are connected to zones are divided into two categories normally open NO or normaly closed NC Some devices have both and the installer can select either d...

Page 7: ...range which equals 3 3 Put the first two bands together which will be 33 4 The third band is red which is equal to 100 5 To get the value of the resistor multiply the first two digits 33 with the thir...

Page 8: ...2 Latch is when the output will go from zero to 12V and stay there until something else tells it to go back to zero volts like a light switch Serial Output 805S Only The serial connection outputs an I...

Page 9: ...progress of such communication To view the communication status proceed as follows 1 Hold down the 0 key until the keypad buzzer sounds twice 2 Press the 9 key The ARMED READY and AWAY LEDs will flash...

Page 10: ...ng mode also known as installer mode To do this an installer code must be entered This code can be a four or six digit code By default 9999 Below is a description of the keys to be used when entering...

Page 11: ...ue that will make the system do what is required or to exit A long beep will be heared if the value is acceptable 3 beeps if there is an error If correct the ready LED will flash showing that the loca...

Page 12: ...as shown in the DEFAULT column in the programming list All user codes will also be defaulted and the master user code will become 1234 Same as a hardware reset 1 Will default the master user code to 1...

Page 13: ...condition and sound the siren 5 Arm Disarm A violation of an Arm Disarm zone will cause the panel to arm or disarm depending on its current state The end of line resistor is required 6 Silent Priority...

Page 14: ...ust be closed and the entry exit delay is operational 11 On On On All zones must be closed and the entry exit delay is operational 12 Off Off On All entry exit and follower zones can be open and the e...

Page 15: ...m The ability to arm the system by holding the 1 key down until the systems begins to arm Entry Exit delay with arm zone When a zone is an arm disarm zone and a key switch or a remote receiver transmi...

Page 16: ...n 0 Disable 1 Enable Location 16 Siren Toot on Arm and Disarm When the alarm is away armed the siren will sound once and when disarmed from the away armed state it will sound twice Value Siren toot on...

Page 17: ...from opening a primary entry exit zone to a person having to entering a valid user code before the alarm is triggered Location 21 Hardware Reset Switch Enable Disable If this option is enabled the al...

Page 18: ...put Explanation 22 Alarm 2 Pulse 2 Burglar alarm registered 23 Panic 1 Pulse 1 Panic triggered 24 Low Battery 0 Battery needs checking 25 Auto test 0 Panel does a test to the monitoring company 26 Dur...

Page 19: ...oth phone numbers are joined to create a single number using pulse dialling 5 Yes Tone Single Both phone numbers are joined to create a single number using tone dialling Location 43 to 46 Primary Comm...

Page 20: ...e of entering a phone number Number to be dialled 0 to get a line 4 second pause 08607051373 Location 48 49 50 51 52 53 54 55 56 57 58 59 60 61 Digits 10 15 10 8 6 10 7 10 5 1 3 7 7 0 NB Location 61 h...

Page 21: ...est 130 131 Low Battery Restoral 113 114 Keypad Fire 132 133 Box Tamper 115 116 Keypad Medical Location 136 to 139 Installers Code The default Installers code is 9999 and should always be changed once...

Page 22: ...rm Location 144 Trouble Display This location is a choice of displaying a trouble condition if a fault occurs for telephone line monitoring and a siren tamper Both or either can be displayed Value Tel...

Page 23: ...s Yes Location 151 Dial Attempts 805 Only The number of times the system will try and dial if communication fails By default this is set to 4 Location 152 to 155 Secondary Communicator Account Code 80...

Page 24: ...Telephone Line Monitoring Fail Output This will trigger an output if the telephone line goes missing Location 168 Telephone Line Monitoring Restore Output This triggers an output when the telephone l...

Page 25: ...nificance of each lit zone LED The system will automatically exit the TROUBLE mode after ten seconds To clear the trouble condition press within 5 seconds of viewing To simply cancel the beeping witho...

Page 26: ...in the away mode Ready Indicator Green The ready indicator comes on when the system is ready to arm Power Indicator Red Two functions 1 Show that the system has power 2 Show that a trouble condition e...

Page 27: ...ode and if any zones have been enabled they will be bypassed automatically This will arm in the stay mode but all entry exit zones will work as if armed in the away mode If the power indicator is flas...

Page 28: ...sabled Stay Go This function offers both away arm and stay arm functionality The system will arm in the stay mode but all entry exit zones will be active To arm in the Stay go mode 1 Press and hold th...

Page 29: ...sarm the system before going into an alarm condition To activate buzz zones 1 Press and hold the 4 key 2 Press the zone number and continue until all have been selected 3 Press to exit Note If a zone...

Page 30: ...seconds 2 Enter master code 1 2 3 4 3 User number 1 4 4 User code 4 4 3 2 Adding a Duress Code A duress code is a code that will disarm the alarm and activate a panic condition when used If system is...

Page 31: ...o get to the keypad after entering the armed premises This zone is generally the last exit point of the building and the first entry point i e the front door of a home Follower Zone A zone that may be...

Page 32: ...users in stand alone mode 16 users when connected to the IDS805 3 LEDs for status information Programmed via an 8 way dip switch All arm or disarm actions logged by user Specifications Supply Voltage...

Page 33: ...n LED Comes on for a second if a known remote transmitter signal is received Remains off if an unknown remote transmitter signal is received Power LED Comes on for a second if an unknown remote transm...

Page 34: ...itter to a user code Step 1 Put dip switch 3 on 3 Step 2 Programming at the keypad To program a remote transmitter to a user code 1 Press and hold the key for 3 seconds 2 Enter the master code 3 Enter...

Page 35: ...ch 4 on then 8 on 2 Press the button on the remote transmitter that you want as the panic button 3 Switch dip switch 8 off 4 Switch dip switch 4 off 4 8 Dip switch 8 goes on last but first off after p...

Page 36: ...next when a button is pressed To set a relay to either pulse or toggle 1 Switch dip switches 5 6 7 on 2 Switch dip switch 8 on 3 Dip switch 1 on for relay 1 to pulse 1 off to toggle relay 1 and dip s...

Page 37: ...wer is lost it will switch to normally closed To setup safe and secure mode 1 Switch dip switch 6 on 2 Switch dip switch 8 on 3 Select which relay by switching either dip switch 1 or 2 or both on 4 Sw...

Page 38: ...Learning a Panic Remote To teach a remote as a panic remote 1 Switch dip switch 6 on 6 2 Press a button on the remote transmitter 3 Switch dip switch 6 off...

Reviews: