MSD-501/502/701/702 User
’s Guide
38
7.4.11 Test pattern
Menu Top
→
OUTPUT TIMING
→
TEST PATTERN
Setting for Each output (COMMON TO OUTA AND OUTB)
Setting value [Fig. 7.5]
VERTICAL LAMP
OFF [Default]
normal video output
50% WHITE
RASTER
V-COLOR BAR
V-GRAY SCALE
RED RASTER GREEN RASTER BLUE RASTER
100% WHITE
RASTER
CROSS HATCH OUTPUT FRAME
VERTICAL
STRIPE
HORIZONTAL
STRIPE
VERTICAL
ZEBRA
H-COLOR BAR
H-GRAY SCALE
HORIZONTAL
LAMP
HORIZONTAL
ZEBRA
[Fig. 7.5] Test pattern
You can select a test pattern to be output instead of displaying video.
All settings of
” will be invalid while a test pattern is displayed.
For “OUTPUT FRAME”: use this pattern if edges are cut off due to enlargement display on the sink device.
Settings of
” in the output side will be adjusted in order to
display the test pattern on full screen.
For test patte
rns other than “OUTPUT FRAME”: video is output on full screen with the resolution set in “
will be invalid.
You can scroll
“COLOR BAR”,”GRAY SCALE”,”LAMP”, and ”ZEBRA” by using arrow keys (
▼ , ▲
,
▼
). The
scroll speed can be set by 3 pixels/a frame up to 30 pixels/ a frame with
▲
and
▼
keys.
You can check the residual image (resolution of moving picture) by displaying
“ZEBRA”.