MSD-501/502/701/702 User
’s Guide
73
■
Screen display during control command execution
When a control command is executed, the user setting for the text of “MEMO” is displayed (1), and if the reply
command is received, the “MEMO” text registered for the reply command is also displayed (2) for one second
(when the control command that is used for checking the reply command is executed).
The received data is displayed (3) for two seconds (when the control command that is used for displaying the
received data is executed).
Examples:
(1)
“SCREEN UP” is registered in the MEMO and the control command is executed.
(2) A reply command,
”SCREEN OK”, is displayed.
(3)
“PROJECTOR LAMP” is registered in the MEMO and “%1LAMP=1000 1
” is received.
(4) Reply command could not be received and retry over occurs.
(1) Only control command
(2) Control command (upper)
Reply command
(
lower)
(3) Received data is displayed.
SEND:SCREEN UP
SEND:SCREEN UP
RECV:SCREEN OK
SEND:PROJECTOR LAMP
RECV:%1LAMP=1000 1
SEND:SCREEN UP
RETRY OVER ERROR
(4) Reply command cannot be
received and a retry error occurs.
[Fig. 7.18] Screen display
If you configure several control commands, or if you display data received from several com ports, the display
time may be shortened by one to two seconds while control commands are being successively executed. If
the received data does not fit in the full screen, the displayed data is scrolled.