MSD-501/502/701/702 User
’s Guide
75
[Table 7.12] Setting value of control command
Item
Setting
Description
Range
COM
CEC
RECV
DISPLAY
yes
no
Set whether received data is displayed or
not.
OFF [Default]
ASCII
HEX
DELIMITER
*1
yes
no
Set the delimiter to be sent at the end of
the received data.
“NONE”: delimiter is not checked and all
received data within the set timeout will be
valid.
Value other than “NONE”: delimiter is
checked and data received before
delimiter will be valid.
NONE [Default]
00 to FF (Hex)
RCV CHECK
*2
yes
no
Set whether reply command that may be
returned is checked or not.
CHECK
NOT CHECK [Default]
TIME OUT
*3 *4
yes
no
Set the timeout time for reply command to
a sent command.
0ms to 99s999ms
[Default]: 0ms
RETRY
*3 *4
yes
no
Set the number of retries to resend the
same command again if no valid response
is replied.
0 to 99 (times)
[Default]: 0
INTERVAL
*3 *4
yes
no
Set the retry interval to resend the
command.
0ms to 99s999ms
[Default] 0ms
ERROR
*3 *4
yes
no
Set whether the next command is to be
executed or not if no valid response is
replied, even after completing retry for the
set number of retries.
STOP [Default]
EXEC: continue
HDMI CEC
control
*7
no
yes
Set the CEC control for the sink devices
connected to OUT1A / OUT2A / OUT1B /
OUT2B.
-: not control [Default]
POWER OFF
POWER ON
Process for
CEC error
no
yes
Set whether the next command is executed
or not if no response is replied from the
sink device that is controlled with CEC.
STOP [Default]
EXEC: continue
MEMO
yes
yes
Register a note up to 14 characters.
The registered note is displayed when the
control command is executed.
20 to 7D in ASCII codes except
for 2C (,)
[Default] 20 (space)
*1 If you set
“RECV DISPLAY” to “OFF”, you cannot set this item.
*2 If you set
“RECV DISPLAY” to “ASCII” or “HEX”, you cannot set this item.
*3 If you set
only “LOOP BACK” of communication ports to “ON”, you do not need to set this item.
*4 If you set
all “RCV CHECK” to “NOT CHECK”, you do not need to set this item.
*5 If you set
“RS:RS-232C” to ”ON”, set “
to
“TRANSMITTER”.
*6 If you set any L
AN connections for “LAN1” to “LAN8” to “ON”, set “
to
“TRANSMITTER”.
*7 CEC: only power ON/OFF of the sink device can be controlled.