MSD-501/502/701/702 User
’s Guide
67
7.11.2 Operation mode
Menu Top
→
COM PORT
→
FUNCTION
Setting for Only RS-232C connector
Setting value RECEIVER [Default], TRANSMITTER
You can set the operation mode to
“RECEIVER” mode in which the MSD is controlled externally or
“TRANSMITTER” mode in which the MSD controls peripheral devices.
The setting of this menu is not updated until the MENU/SET key is pressed. Make sure to press the
MENU/SET key to update the setting.
7.11.3 RS-232C transmission between control devices
Menu Top
→
COM PORT
→
OUT B SCI CONNECT
Setting value
Setting
Operation
OFF [Default]
The RS-232C connector of the MSD works according to the setting of
”.
OUT1B
Communicates between the RS-232C connector of the MSD and the RS-232C
connector of the HDC receiver that is connected to a digital signal output connector for
extension.
The RS-232C connector of the MSD cannot be used for communication command
control to the MSD from PCs or control command output to external devices from the
MSD.
OUT2B
You can set the connection between the RS-232C connector of the MSD and the RS-232C connector of the
HDC receiver that is connected to a digital signal output connector for extension.
【