MSD-501/502/701/702 User
’s Guide
45
7.7 Setting input timing
You can set input timing of analog input video if signal is input.
Since the MSD loads the optimal table from the built-in tables and adjusts the input timing automatically, you
do not need to set this menu. However, if signal which are not registered in the MSD tables are input or if part
of the output video is cut off by using the standard table registered in the MSD, set the input timing manually.
For digital inputs, you do not need to set the input timing, but if part of the video is cut off, adjust the input
timing finely.
[Table 7.4] Settable items
Function
Analog input
Digital input
Partly 1
Cannot be set
The total number of horizontal dots
Partly 1, Partly 2
Partly 2
Can be set
Can be set
Can be set
Can be set
Automatic measurement of start position
Can be set
Cannot be set
Automatic setting of input timing
Can be set
Cannot be set
Partly 3
Can be set
Partly 1
Cannot be set
Partly 1
Cannot be set
Partly 1: can be set only if analog RGB / analog YPbPr signal is input.
Partly 2: only displayed if analog video signal is input or for digital input.
Partly 3: can be set only if the device data of input signal is registered in the
MSD.
7.7.1 Automatic measurement
Menu Top
→
INPUT TIMING
→
AUTO SETUP
Setting for Each input/input signal
Setting value
・
NORMAL MODE [Default]
・
4:3
・
5:3
・
16:10
・
NEXT ASPECT
・
5:4
・
16:9
Analog RGB/analog YPbPr input video is measured to set
7.7.2 The total number of horizontal dots
”,
” automatically.
Normally, select ”NORMAL MODE” (Automatic measurement of start position and active area). If edges of
video are not displayed correctly, use this mode to set the start position and active area automatically.
If the total number of horizontal dots is not correct, the aspect ratio is not matched even though automatic
measurement is set to perform with
the “NORMAL MODE”. In this case, select ”NEXT ASPECT” (Auto
measurement taking into account aspect ratio) for the measurement function. If the aspect ratio of the input
signal is known, you can directly specify the aspect ratio to correctly perform the automatic measurement.
If input signal is not registered in the MSD, use this function.