MSD-501/502/701/702 User
’s Guide
49
7.7.7 Loading device data
Menu Top
→
INPUT TIMING
→
LOAD
Setting for Each input/input signal
Device data whose input timing is registered can be loaded according to the input signal.
The setting of this menu is not updated until the MENU/SET key is pressed. Make sure to press the
MENU/SET key to update the setting.
[Table 7.5] Items to be loaded
Input signal
Item
Analog
Registered device data will be loaded.
Use this menu in the following cases:
Several device data with the same frequency of synchronous signal and different input
timings is registered.
You want to set the input timing again.
Digital
The value that is automatically detected by the MSD will be set.
Use this menu to restore the input timing to the original value.
7.7.8 Registering device data
Menu Top
→
INPUT TIMING
→
SAVE
Setting for Each input/input signal
You can save up to 99 input timing settings to the device data.
From the next time, when the same signal is input to other channel, video will be displayed with the registered
timing.
The setting of this menu is not updated until the MENU/SET key is pressed. Make sure to press the
MENU/SET key to update the setting.
7.7.9 Tracking
Menu Top
→
INPUT TIMING
→
TRACKING
Setting for Each input/input signal
Setting value 0 to 63 [Default]:0
You can adjust the tracking of analog RGB/analog YPbPr input video.